This experimental investigation reports the convective heat transfer coefficient around the rotor of a transonic turbine stage. Both time-resolved and time-averaged aspects are addressed. The measurements are performed around the rotor blade at 15, 50, and 85% span as well as on the rotor tip and the hub platform. Four operating conditions are tested covering two Reynolds numbers and three pressure ratios. The tests are performed in the compression tube turbine test rig CT3 of the von Karman Institute, allowing a correct simulation of the operating conditions encountered in modern aero-engines. The time-averaged Nusselt number distribution shows the strong dependence on both blade Mach number distribution and Reynolds number. The time-resolved heat transfer rate is mostly dictated by the vane trailing edge shock impingement on the rotor boundary layer. The shock passage corresponds to a sudden heat transfer increase. The effects are more pronounced in the leading edge region. The increase of the stage pressure ratio causes a stronger vane trailing edge shock and thus larger heat transfer fluctuations. The influence of the Reynolds number is hardly visible.
Skip Nav Destination
Article navigation
October 2002
Technical Papers
Unsteady Rotor Heat Transfer in a Transonic Turbine Stage
F. Didier,
F. Didier
Von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Search for other works by this author on:
R. De´nos, Mem. ASME,
R. De´nos, Mem. ASME
Von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Search for other works by this author on:
T. Arts
T. Arts
Von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Search for other works by this author on:
F. Didier
Von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
R. De´nos, Mem. ASME
Von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
T. Arts
Von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Contributed by the International Gas Turbine Institute and presented at the International Gas Turbine and Aeroengine Congress and Exhibition, Amsterdam, The Netherlands, June 3–6, 2002. Manuscript received by the IGTI, September 21, 2001. Paper No. 2002-GT-30195. Review Chair: E. Benvenuti.
J. Turbomach. Oct 2002, 124(4): 614-622 (9 pages)
Published Online: November 7, 2002
Article history
Received:
September 21, 2001
Online:
November 7, 2002
Citation
Didier , F., De´nos , R., and Arts, T. (November 7, 2002). "Unsteady Rotor Heat Transfer in a Transonic Turbine Stage ." ASME. J. Turbomach. October 2002; 124(4): 614–622. https://doi.org/10.1115/1.1505850
Download citation file:
Get Email Alerts
Related Articles
Analysis of Unsteady Tip and Endwall Heat Transfer in a Highly Loaded Transonic Turbine Stage
J. Turbomach (July,2012)
Transonic Turbine Stage Heat Transfer Investigation in Presence of Strong Shocks
J. Turbomach (July,2008)
A Study of Advanced High-Loaded Transonic Turbine Airfoils
J. Turbomach (October,2006)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Introduction
Turbine Aerodynamics: Axial-Flow and Radial-Flow Turbine Design and Analysis
Introduction
Design and Analysis of Centrifugal Compressors