A torque converter was tested for two turbine/pump rotational speed ratios, 0.065 and 0.800, and a laser velocimeter was used to measure three components of velocity within the pump. Shaft encoders were used to record the instantaneous pump angular position, which was correlated with the velocities. Average flow velocity profiles were obtained for the pump inlet, mid-, and exit planes. Large separation regions were seen in the mid- and exit planes of the pump for a speed ratio of 0.800. Strong counterclockwise secondary flows were observed in the midplane and strong clockwise secondary flows were seen in the exit plane of the pump for all conditions; vorticities were evaluated and are reported. Velocity data were also used to find the torque distribution. For both speed ratios the torque was approximately evenly distributed between the inlet and exit. Finally, slip factors were evaluated at the mid-and exit planes. At the midplane they were approximately the same as for conventional centrifugal pumps; however, at the exit plane the slip factors are larger than for centrifugal pumps.
Skip Nav Destination
Article navigation
July 1996
Research Papers
Laser Velocimeter Measurements in the Pump of an Automotive Torque Converter: Part I—Average Measurements
J. K. Gruver,
J. K. Gruver
Department of Mechanical, Aerospace, and Nuclear Engineering, ROMAC Laboratories, University of Virginia, Charlottesville, VA 22903
Search for other works by this author on:
R. D. Flack,
R. D. Flack
Department of Mechanical, Aerospace, and Nuclear Engineering, ROMAC Laboratories, University of Virginia, Charlottesville, VA 22903
Search for other works by this author on:
K. Brun
K. Brun
Department of Mechanical, Aerospace, and Nuclear Engineering, ROMAC Laboratories, University of Virginia, Charlottesville, VA 22903
Search for other works by this author on:
J. K. Gruver
Department of Mechanical, Aerospace, and Nuclear Engineering, ROMAC Laboratories, University of Virginia, Charlottesville, VA 22903
R. D. Flack
Department of Mechanical, Aerospace, and Nuclear Engineering, ROMAC Laboratories, University of Virginia, Charlottesville, VA 22903
K. Brun
Department of Mechanical, Aerospace, and Nuclear Engineering, ROMAC Laboratories, University of Virginia, Charlottesville, VA 22903
J. Turbomach. Jul 1996, 118(3): 562-569 (8 pages)
Published Online: July 1, 1996
Article history
Received:
February 4, 1994
Online:
January 29, 2008
Citation
Gruver, J. K., Flack, R. D., and Brun, K. (July 1, 1996). "Laser Velocimeter Measurements in the Pump of an Automotive Torque Converter: Part I—Average Measurements." ASME. J. Turbomach. July 1996; 118(3): 562–569. https://doi.org/10.1115/1.2836703
Download citation file:
Get Email Alerts
The Cooling Effect of Combustor Exit Louver Scheme on a Transonic Nozzle Guide Vane Endwall
J. Turbomach (July 2025)
Aerodynamic Performance Evaluation of Subsonic Compressor Cascade Blade With Leading-Edge Damage
J. Turbomach (July 2025)
Thermohydraulic Performance and Flow Structures of Diamond Pyramid Arrays
J. Turbomach (July 2025)
Related Articles
Laser Velocimeter Measurements in the Turbine of an Automotive Torque Converter: Part I—Average Measurements
J. Turbomach (July,1997)
Laser Velocimeter Measurements in the Turbine of an Automotive Torque Converter: Part II—Unsteady Measurements
J. Turbomach (July,1997)
Laser Velocimeter Measurements in the Pump of an Automotive Torque Converter: Part II—Unsteady Measurements
J. Turbomach (July,1996)
Flow Characteristics of a Centrifugal Pump
J. Fluids Eng (June,1994)
Related Proceedings Papers
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression System: A Practical Approach, Third Edition