Abstract

This study reports the development of extreme meteorological year (XMY) data for simulating buildings that are heated and cooled entirely by ambient energy in four climates varying in outdoor temperature and cloudiness. Electrification of conventional buildings is insufficient to meet climate goals since nearly half of U.S. electricity will still be produced from fossil fuels by 2050. Ambient-conditioned buildings depend on non-fossil sources such as the sun for heating and nighttime air or sky radiation for cooling. Such buildings are more susceptible to weather variability than conventional buildings, which simply use more auxiliary energy whenever weather conditions are challenging. On the other hand, ambient-conditioned buildings are more resilient to power outages so long as the design accounts for unusual weather during extreme years to consistently maintain indoor comfort. Ambient-conditioned buildings designed to remain comfortable with typical meteorological year (TMY2020) data produced up to over 1000 h per year of uncomfortable indoor temperature during the years (1998–2020) from which the TMY was derived. Parameters related to outdoor air temperature, sky temperature, and insolation were found to be unreliable for identifying the most challenging years. Rather, a whole-building model allowed the identification of the two most challenging years for heating and cooling, respectively. An XMY file concatenated from the most challenging summer and the most challenging winter provided a good match of indoor temperature predictions to those from the full individual years. This new XMY file facilitates the design of ambient-conditioned buildings for reliable indoor comfort.

Graphical Abstract Figure
Graphical Abstract Figure
Close modal

References

1.
Architecture2030
,
2023
, “Why the Built Environment?” https://www.architecture2030.org/why-the-built-environment/
2.
Global ABC
,
2017
, “Global Alliance for Buildings and Construction, Global Status Report for Buildings and Construction.”
3.
EIA
,
2022
, “Annual Energy Outlook.” US Energy Information Administration, https://www.eia.gov/outlooks/aeo/
4.
Sharp
,
M. K.
,
2023
, “Flouting Conventional Wisdom: Homes Conditioned Entirely by Ambient Energy.” Solar Today. pp.
34
39
.
5.
Sherburne
,
M.
,
2010
, “The House of the Day After Tomorrow.” Technology Review, https://www.technologyreview.com/2010/06/22/202508/the-house-of-the-day-after-tomorrow/
6.
Crawley
,
D. B.
, and
Lawrie
,
L. K.
,
2015
, “
Rethinking the TMY: Is ‘Typical’ Meteorological Year Best for Building Simulation?
,”
14th Conference on International Building Performance Simulation Association
,
Hyderabad, India
,
Dec. 7–9
, pp.
2655
2662
.
7.
Crawley
,
D. B.
, and
Lawrie
,
K.
,
2019
, “
Should We Be Using Just ‘Typical’ Weather Data in Building Performance Simulation?
,”
Proceedings of BS 2019
,
Rome, Italy
,
Sept. 2–4
, pp.
4801
4808
.
8.
Gasparella
,
A.
,
Crawley
,
D. B.
,
Pernigotto
,
G.
,
Prada
,
A.
, and
Lawrie
,
L.
,
2021
, “
Extreme Weather Data in Building Performance Simulation
,”
Building Simulation 2021
,
Bruges, Belgium
,
Sept. 2021
, pp.
894
901
.
9.
Sharp
,
M. K.
,
2023
, “
A Methodology to Assess the Suitability of Typical Meteorological Year Weather Data for Simulating the Performance of Buildings Conditioned Entirely by Ambient Energy
,”
ASME J. Eng. Sustainable Bldg. Cities
,
4
(
4
), p.
044501
.
10.
Sharp
,
M. K.
,
2021
, “
Indoor Comfort Achieved Exclusively From Ambient Sources Across US Climates
,”
ASME J. Sol. Energy Eng.
,
143
(
6
), p.
061005
.
11.
Sharp
,
M. K.
,
2022
, “
Sky Radiation Decreases Thermal Mass Requirements to Achieve 100% Ambient Cooling in Hot US Climates
,”
ASME J. Eng. Sustainable Bldg. Cities.
,
3
(
2
), p.
021003
.
12.
NSRDB
,
2023
, “Typical Meteorological Year (TMY).” National Solar Radiation Data Base. https://nsrdb.nrel.gov/data-sets/tmy
13.
Wang
,
Z.
,
de Dear
,
R.
,
Luo
,
M.
,
Lin
,
B.
,
He
,
Y.
,
Ghahramani
,
A.
, and
Zhu
,
Y.
,
2018
, “
Individual Difference in Thermal Comfort: A Literature Review
,”
Build. Environ.
,
138
, pp.
181
193
.