A feasibility study of using solar liquid-desiccant air conditioner (LDAC) developed in Queensland has been undertaken. The system uses high effectiveness cross-flow polymer plate heat exchanger (PPHE), as the absorber unit. Outside air is dehumidified by strong liquid desiccant and indirectly cooled within the PPHE. The warm dry air is, subsequently, cooled and humidified through a direct evaporative cooler and supplied to the conditioned space. The weak desiccant solution from the absorber unit is concentrated in a scavenger air regenerator using hot water from flat plate solar collectors. The prototype of the absorber unit of the liquid-desiccant system has been tested under the summer conditions of Brisbane, using lithium chloride as the absorbent solution. The results of the experiments indicate that they are in good agreement with a previously developed model for the absorber unit. The tests further reveal that the unit has a satisfactory performance in controlling the air temperature and relative humidity when installed on a commercial site of area in Brisbane. A commercialization strategy has been proposed in this study for a solar operated LDAC in Queensland and compared with the conventional direct expansion (DX) system. Based on the computer modeling results obtained from the system simulation for a building in Cairns, North Queensland, the operating costs of the LDAC are significantly lower than its conventional DX counterpart. This study further reveals that using the solar operated LDAC with a storage system will result in considerable savings in operating costs when compared with the equivalent gas-fired system. A simple payback of five years was determined for the solar components in this study.
Skip Nav Destination
e-mail: shahaḇalizadeh@hotmail.com
Article navigation
Research Papers
A Feasibility Study of Using Solar Liquid-Desiccant Air Conditioner in Queensland, Australia
Shahab Alizadeh
Shahab Alizadeh
Faculty of Built Environment and Engineering,
e-mail: shahaḇalizadeh@hotmail.com
Queensland University of Technology
, GPO Box 2434, Brisbane 4001, Australia
Search for other works by this author on:
Shahab Alizadeh
Faculty of Built Environment and Engineering,
Queensland University of Technology
, GPO Box 2434, Brisbane 4001, Australiae-mail: shahaḇalizadeh@hotmail.com
J. Sol. Energy Eng. May 2008, 130(2): 021005 (9 pages)
Published Online: March 10, 2008
Article history
Received:
October 29, 2005
Revised:
August 25, 2007
Published:
March 10, 2008
Citation
Alizadeh, S. (March 10, 2008). "A Feasibility Study of Using Solar Liquid-Desiccant Air Conditioner in Queensland, Australia." ASME. J. Sol. Energy Eng. May 2008; 130(2): 021005. https://doi.org/10.1115/1.2844426
Download citation file:
Get Email Alerts
Mass Flow Control Strategy for Maximum Energy Extraction in Thermal Energy Storage Tanks
J. Sol. Energy Eng (December 2025)
Exergy Optimization of a Hybrid Multi-Evaporative Desalination Plant Powered by Solar and Geothermal Energy
J. Sol. Energy Eng (June 2025)
Correlation for Maximum Heat Transfer Between Fluidized Bed and Its Wall and Application to Solar Power Plants
J. Sol. Energy Eng (June 2025)
Related Articles
A Liquid Desiccant System for Solar Cooling and Dehumidification
J. Sol. Energy Eng (August,2004)
Simulation and Experimental Analysis of a Solar Driven Absorption Chiller With Partially Wetted Evaporator
J. Sol. Energy Eng (February,2010)
A Study of the Performance of a Hybrid Liquid Desiccant Cooling System Using Lithium Chloride
J. Sol. Energy Eng (February,2003)
Experimental Investigation of a LiCl-Water Open Absorption System for Cooling and Dehumidification
J. Sol. Energy Eng (May,2004)
Related Proceedings Papers
Related Chapters
Characteristics, Components, and Performance of A/C System Exchangers
Heat Exchanger Engineering Techniques
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential