A model to determine the instantaneous transmittance of glazing for specific direct and diffuse solar radiation conditions is developed. Plots illustrative of the generic behavior of the mean monthly hourly transmittance of glazings in different planes are presented. Using test reference year meteorological data for 29 western European locations, limiting values are determined for clearness indices, orientations, and slopes for which an isotropic diffuse assumption is valid for calculating mean daily transmittance.
Issue Section:
Technical Papers
1.
Burek
, S. A. M.
, Norton
, B.
, and Probert
, S. D.
, 1989
, “Transmission of Insolation Through Transparent and Semi-Transparent Materials
,” Sol. Energy
, 42
, pp. 457
–475
.2.
Karlsson
, J.
, Rubin
, M.
, and Roos
, A.
, 2001
, “Evaluation of Predictive Models for the Angle-Dependent Total Solar Energy Transmittance of Glazing Material
,” Sol. Energy
, 71
, pp. 23
–31
.3.
Arthur
, A. E.
, and Norton
, B.
, 1990
, “The Variation of Solar Transmittance with Angle of Incidence
,” Int. J. Ambient Energ.
, 11
, pp. 137
–148
.4.
Klein
, S. A.
, 1979
, “Calculation of the Monthly-Average Transmittance-Absorptance Product
,” Sol. Energy
, 23
, pp. 547
–551
.5.
Gueymard
, C.
, 1989
, “A Simplified Model for the Computation of Radiation Transmission Through a Series of Semi-Transparent Plates
,” Sol. Energy
, 42
, pp. 433
–440
.6.
Klucher
, T. M.
, 1979
, “Evaluation of Models to Predict Insolation on Tilted Surfaces
,” Sol. Energy
, 23
, pp. 111
–114
.7.
Hay, J. E., and Davies, J. A., 1980, “Calculation of the Solar Radiation Incident on an Inclined Surface,” Proc. of the First Canadian Solar Radiation Data Workshop, J. E. Hay and T. K. Won, Eds., Toronto, pp. 59–72.
8.
Duffie, J. A., and Beckman, W. A., 1991, Solar Engineering of Thermal Processes, 2nd Edition, John Wiley & Sons, New York.
9.
Perez
, R.
, Stewart
, R.
, Arbogast
, C.
, Seals
, R.
, and Scott
, J.
, 1986
, “An Anisotropic Hourly Diffuse Radiation Model for Sloping Surfaces: Description, Performance Validation and Site Dependency Evaluation
,” Sol. Energy
, 36
, pp. 481
–497
.10.
Perez
, R.
, Seals
, R.
, Zelenka
, A.
, and Ineichen
, P.
, 1990
, “Climatic Evaluation of Models That Predict Hourly Direct Irradiance From Hourly Global Irradiance: Prospects for Performance Improvements
,” Sol. Energy
, 44
, pp. 99
–108
.11.
Perez
, R.
, Ineichen
, P.
, Seals
, R.
, and Zelenka
, A.
, 1990
, “Marking Full Use of the Clearness Index for Parameterizing Hourly Insolation Conditions
,” Sol. Energy
, 45
, pp. 111
–114
.12.
Brunger
, A. P.
, and Hooper
, F. C.
, 1993
, “Anisotropic Sky Radiance Model Based on Narrow Yield of View Measurements of Shortwave Radiance
,” Sol. Energy
, 51
, pp. 53
–64
.13.
Brunger, A. P., and Hollands, K. G. T., 1995, “Solar Irradiance Modelling for High Latitudes,” Final Report, Resources Naturelles Canada-CANMET.
14.
Karlsson, J., 2001, “Windows—Optical Performance and Energy Efficiency,” Ph.D. thesis, Uppsala Univ., Uppsala, Sweden.
15.
Brandemuehl
, M. J.
, and Beckman
, W. A.
, 1980
, “Transmission of Diffuse Radiation Through CPC and Flat-Plate Collector Glazings
,” Sol. Energy
, 24
, pp. 511
–513
.16.
Miller, A. A., and Thompson, J., 1979, Meteorology, 3rd Edition, Charles E. Merrill, Columbus, OH.
17.
Davis
, R.
, Ridgeway
, W. L.
, and Kim
, K. E.
, 1984
, “Spectral Absorption of Solar Radiation in Cloudy Atmospheres: A 20 cm−1 Model
,” J. Atmos. Sci.
, 41
, pp. 2126
–2127
.18.
Suehrcke
, H.
, and McCormick
, P. G.
, 1989
, “The Distribution of Average Instantaneous Solar Radiation Over the Day
,” Sol. Energy
, 42
, pp. 303
–309
.19.
Louche
, A.
, Maurel
, M.
, Simonnot
, G.
, Peri
, O.
, and Iqbal
, M.
, 1987
, “Determination of A˚ngstro¨m’s Turbidity Coefficient for Direct Total Solar Irradiance Measurements
,” Sol. Energy
, 38
, pp. 89
–96
.20.
Bokoye
, A. I.
, de La Casiniere
, A.
, and Cabot
, T.
, 1997
, “A˚ngstro¨m’s Turbidity Parameters and Aerosol Optical Thickness: A Study Over 500 Solar Beam Spectra
,” J. Geophys. Res.
, 102
, pp. 21914
–21950
.21.
Bosca
, J. V.
, Canada
, J.
, and Pinazo
, J. M.
, 2001
, “A Comparative Analysis of Broadband Global and Diffuse Irradiance Methods to Determine A˚ngstro¨m’s Turbidity Coefficient
,” Int. J. Ambient Energ.
, 22
, pp. 73
–82
.22.
Liu
, B. Y. H.
, and Jordan
, R. C.
, 1963
, “The Long Term Average Performance of Flat-Plate Solar Energy Collectors
,” Sol. Energy
, 7
, p. 53
53
.23.
Ineichen
, P.
, Guisan
, O.
, and Perez
, R.
, 1990
, “Ground-Reflected Radiation and Albedo
,” Sol. Energy
, 44
, pp. 207
–214
.24.
Anon, Test Reference Years: Weather Data Sets for Computer Simulation of Solar Energy Systems and Energy Consumption in Buildings, Commission of the European Communities, Brussels, Belgium, 1985.
Copyright © 2003
by ASME
You do not currently have access to this content.