Abstract

This report deals with the experimental study of seismic response behavior of piping systems in industrial facilities such as petrochemical, oil refinery, and nuclear plants. Special attention is focused on the nonlinear dynamic response of piping systems due to frictional vibration appearing in piping and supporting devices. A three-dimensional mock-up piping and supporting structure model wherein piping is of 30-m length and 200-mm diameter is excited by a large-scale (15 m × 15 m) shaking table belonging to the National Research Institute for Earth Science and Disaster Prevention in Tsukuba, Ibaraki. Power spectra of the response vibration and the loading-response relationship in the form of a hysteresis loop under several loading conditions are obtained. The response reduction effect caused by frictional vibration is evaluated and demonstrated in terms of “response reduction factor.”

1.
Geraetz, L. H., and Lemaire, H., 1984, “Gap Influence on Seismic Response of Piping,” Transaction of 6th SMiRT, K10/8, pp. 1–5.
2.
Kobayashi, H., et al., 1987, “Dynamic Response of the Piping System on the Rock Structure with Gaps and Frictions,” Transaction of 9th SMiRT, K16/9, pp. 995–1000.
3.
Sone, A., and Suzuki, K., 1989, “A Practical Method for Obtaining Nonlinear Response Properties Considering the Effect of Gap and Friction,” ASME PVP Vol. 182, pp. 31–36.
4.
Sone, A., and Suzuki, K., 1990, “A Simplified Response Analysis of Piping-Supporting System Considering the Energy Absorbing Effect due to Gap and Friction,” ASME PVP Vol. 197, pp. 3–10.
5.
Vayda
J. P.
,
1981
, “
Influence of Gap Size on the Dynamic Behavior of Piping Systems
,”
Nuclear Engineering and Design
, Vol.
67
, pp.
145
164
.
This content is only available via PDF.
You do not currently have access to this content.