Colonoscopy can be associated with many problems, such as mechanical trauma due to the distal tip contacting the colon wall or health issues due to the extended use of anesthesia. In order to eliminate these complications, an automatically adjustable colonoscope was designed. This device uses sensors, actuators, and a control system to automatically position the distal tip in the center of the colon lumen. The sensors were tested to determine their ability to accurately sense the distance from the tip to the surface of a white PVC tube. The actuators were tested to determine the correlation between motor rotation and displacement of the distal tip. The control system was tested to assess the ability of the device to position the tip in the center of the test tube and the ability to navigate through a flat test course. It was determined that the sensors could accurately determine distances from 0 mm to 15 mm from the test surface in all test conditions. The motors for up-down movement and left-right movement of the colonoscope had response times of 0.57 s and 0.69 s, respectively, when the motors were rotated from 0 deg to 90 deg. The control system was able to safely move the colonoscope tip away from all walls of the test apparatus. It was also able to navigate through the flat test course without coming in contact with the walls. The automatically adjustable colonoscope has demonstrated that it can safely and effectively position the distal tip to avoid contact with the walls of the test surface.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Development of an Automatically Adjustable Colonoscope
Jonathan Litten
Jonathan Litten
Ohio University
Search for other works by this author on:
JungHun Choi
Ohio University
Jonathan Litten
Ohio University
J. Med. Devices. Jun 2011, 5(2): 027535 (1 pages)
Published Online: June 15, 2011
Article history
Online:
June 15, 2011
Published:
June 15, 2011
Citation
Choi, J., and Litten, J. (June 15, 2011). "Development of an Automatically Adjustable Colonoscope." ASME. J. Med. Devices. June 2011; 5(2): 027535. https://doi.org/10.1115/1.3591379
Download citation file:
1,478
Views
Get Email Alerts
Cited By
Related Articles
Erratum: “Control of Flexible-Link Multiple Manipulators” [ASME J. Dyn. Syst., Meas., and Control, 124 , No. 1, pp. 64–75]
J. Dyn. Sys., Meas., Control (March,2003)
Automated 3D Mosaicing and Scan Trajectories for Surveillance of Bladder Cancer
J. Med. Devices (June,2011)
Development of an Automated Steering Mechanism for Bladder Urothelium Surveillance
J. Med. Devices (March,2009)
Comparison of Video Laryngoscopy Technologies
J. Med. Devices (June,2009)
Related Chapters
QP Based Encoder Feedback Control
Robot Manipulator Redundancy Resolution
Feedback-Aided Minimum Joint Motion
Robot Manipulator Redundancy Resolution
Self-Motion Planning with ZIV Constraint
Robot Manipulator Redundancy Resolution