Weakening of muscle and bone tissue after merely a week of exposure to a microgravity environment has been demonstrated to adversely affect the physiological health of astronauts . Innovative solutions meant to replace traditionally bulky resistance-based devices are highly sought by burgeoning private space travel companies as well as other ambitious spaceflight programs that require a robust and effective solution for long durations in microgravity . The purpose of this study is to explore the unique contributions of exoskeleton technology in providing an effective, compact and elegant preventative device through assessing the current ability of exoskeleton technologies in stressing the body, formulating design requirements of an exoskeleton device and highlighting the areas of exoskeleton development that require further work in the realization of a robust microgravity-atrophy solution. An understanding of the abilities and shortcomings of current exoskeleton technologies is necessary to develop and streamline advanced forms of today's space physiological devices . The physiologically familiar structure of an exoskeleton, being built around the human form, would also provide for a greater degree of compactness, affecting everything from launch expenses to living arrangements in any space module. A more effective and persistent method of stressing the body will ultimately allow for a drastic decrease in bone and muscle atrophy, requiring less therapy should any space traveler return to a gravity environment as well as preventing various related ailments during their time in space. In conducting the study, a literature search was performed to identify fundamental design parameters. Designs were then formulated to best fit the required design specifications with difficult or absent features being noted. Initial design concepts based on traditional resistance-based solutions were also developed to further characterize the particular requirements that an exoskeleton would be required to fulfill. These design concepts were then steadily revised into a potential force generation mechanism and device architecture based on factors including human comfort, force generation, effective ranges of motion, materials and geometry. An appraisal of current exoskeleton technology in actualizing the proposed designs and design specifications provides a basis for analysis. The study has uncovered the strong points in exoskeletal designs as well as the major hurdles that, once crossed, will allow exoskeletal technologies to be a viable application in bone and muscle therapies, both in microgravity environments as well as gravity environments. A large hurdle lies in current exoskeleton technologies still utilizing bulky components but past trends have demonstrated a reliable miniaturization in the technology. Particularly important exercises and ranges of motion have been identified and initial designs formulated based on the physiological requirements. The study has demonstrated the need for more efforts in formulating innovative solutions to space-based physiology problems as well as explicitly listing design parameters required for any potential exoskeleton solution.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Exoskeleton Solutions to Bone and Muscle Atrophy Within Microgravity Environments
V. Tiruvadi,
V. Tiruvadi
University of Pennsylvania
, Department of Bioengineering, Philadelphia, PA 19104
Search for other works by this author on:
C. Lessard
C. Lessard
Texas A&M University
, Department of Biomedical Engineering, College Station, TX 77843
Search for other works by this author on:
V. Tiruvadi
University of Pennsylvania
, Department of Bioengineering, Philadelphia, PA 19104
C. Lessard
Texas A&M University
, Department of Biomedical Engineering, College Station, TX 77843J. Med. Devices. Jun 2009, 3(2): 027540 (1 pages)
Published Online: July 9, 2009
Article history
Published:
July 9, 2009
Citation
Tiruvadi, V., and Lessard, C. (July 9, 2009). "Exoskeleton Solutions to Bone and Muscle Atrophy Within Microgravity Environments." ASME. J. Med. Devices. June 2009; 3(2): 027540. https://doi.org/10.1115/1.3147523
Download citation file:
740
Views
Get Email Alerts
Cited By
Related Articles
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Development of a Product for Reducing Orthodontic Treatment Duration
J. Med. Devices (June,2010)
An Engineering Approach for Quantitative Analysis of the Lengthwise Strokes in Massage Therapies
J. Med. Devices (December,2008)
Design and Prototyping of a Low-Cost Portable Mechanical Ventilator
J. Med. Devices (June,2010)
Related Chapters
Occlusion Identification and Relief within Branched Structures
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Basic Principles and Current Treatments
Medical Devices for Respiratory Dysfunction: Principles and Modeling of Continuous Positive Airway Pressure (CPAP)
The Application of Functional Analytic Method to an HIV Model
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)