ISO 10993-4 in vivo thrombogenicity testing is frequently performed for regulatory approval of many blood-contacting medical devices and is often a key part of submission packages. Given the current state of in vivo thrombogenicity assays, a more robust and reproducible assay design, including in vitro models, is needed. This study describes an in vitro assay that integrates freshly harvested ovine blood containing minimal heparin in a closed pumped loop. To confirm the reproducibility of this assay, control materials were identified that elicited either a positive or a negative thrombogenic response. These controls demonstrated reproducibility in the resulting thrombogenicity scores with median scores of 5 and 0 for the positive and negative controls, respectively, which also demonstrated a significant difference (p < 0.0001). For a direct comparison of the in vitro blood loop assay to the traditional in vivo nonanticoagulated venous implant (NAVI) assay, seven sheep were used as blood donors for the loop and then as subjects for an NAVI assay. In each assay—loop or NAVI—three study articles were used: the positive and negative controls and a marketed, approved catheter. The resulting thrombogenicity scores were similar when comparing the loop to the NAVI results. For each study article, the median thrombogenicity scores were the same in these two different assays, being 0, 1, and 5 for the negative control, the marketed catheter, and the positive control, respectively. These data suggest that the in vitro assay performs similarly to the in vivo NAVI assay. This in vitro blood loop method has the potential to predict a materials' in vivo thrombogenicity, can substantially de-risk the materials or coating selection process, and may eventually be able to replace the in vivo models currently in use.

References

1.
ISO
,
2002
, “
Biological Evaluation of Medical Devices—Part 4: Selection of Tests for Interactions With Blood
,”
Association for the Advancement of Medical Instrumentation
, Arlington, VA, Standard No. ISO 10993-4.
2.
ASTM
,
2009
, “
Standard Practice for Assessment of Hemolytic Properties of MATERIALS, Medical and Surgical Materials and Devices; Anesthetic and Respiratory Equipment; Manufacture of Pharmaceutical Products
,”
American Society for Testing and Materials, ASTM International
, West Conshohocken, PA, Standard No. F7560-00.
3.
Wolf
,
M. F.
, and
Anderson
,
J. M.
,
2012
, “
Practical Approach to Blood Compatibility Assessments: General Considerations and Standards
,”
Biocompatibility and Performance of Medical Devices
,
J.-P.
Boutrand
, ed.,
Woodhead Publishing
,
Oxford, UK
.
4.
U.S. Food and Drug Administration
,
2014
, “
Methods for Thrombogenicity Testing
,”
Public Workshop
, U.S. Food and Drug Administration, White Oak Campus, Silver Spring, MD, Apr. 14.
5.
ISO/DIS
,
2016
, “
Biological Evaluation of Medical Devices—Part 4: Selection of Tests for Interactions With Blood
,”
Draft International Standard, International Organization for Standardization
, Geneva, Switzerland, Standard No. ISO/DIS 10993-4.
6.
Krajewski
,
S.
,
Neumann
,
B.
,
Kurz
,
J.
,
Perle
,
N.
,
Avci-Adali
,
M.
,
Cattaneo
,
G.
, and
Wendel
,
H. P.
,
2015
, “
Preclinical Evaluation of the Thrombogenicity and Endothelialization of Bare Metal and Surface-Coated Neurovascular Stents
,”
Am. J. Neuroradiol.
,
36
(
1
), pp.
133
139
.
7.
van Oeveren
,
W.
,
Tielliu
,
I. F.
, and
de Hart
,
J.
,
2012
, “
Comparison of Modified Chandler, Roller Pump, and Ball Valve Circulation Models for In Vitro Testing in High Blood Flow Conditions: Application in Thrombogenicity Testing of Different Materials for Vascular Applications
,”
Int. J. Biomater.
,
2012
(
2012
), p.
673163
.
8.
Walker
,
E. K.
,
Nauman
,
E. A.
,
Allain
,
J. P.
, and
Stanciu
,
L. A.
,
2015
, “
An In Vitro Model for Preclinical Testing of Thrombogenicity of Resorbable Metallic Stents
,”
J. Biomed. Mater. Res. A.
,
103
(
6
), pp.
2118
2125
.
9.
Sukavaneshvar
,
S.
,
2016
, “
Device Thrombosis and Pre-Clinical Blood Flow Models for Assessing Antithrombogenic Efficacy of Drug-Device Combinations
,”
Adv. Drug Delivery Rev.
(in press).
10.
Hastings
,
S. M.
,
Deshpande
,
S. R.
,
Wagoner
,
S.
,
Maher
,
K.
, and
Ku
,
D. N.
,
2016
, “
Thrombosis in Centrifugal Pumps: Location and Composition in Clinical and In Vitro Circuits
,”
Int. J. Artif. Organs
,
39
(
4
), pp.
200
204
.
11.
Miller
,
R.
,
Fainerman
,
V. B.
,
Wustneck
,
R.
,
Kragel
,
J.
, and
Trukhin
,
D. V.
,
1998
, “
Characterization of the Initial Period of Protein Adsorption by Dynamic Surface Tension Measurements Using Different Drop Techniques
,”
Colloids Surf. A
,
131
(
1–3
), pp.
225
230
.
12.
Grove
,
K.
,
Deline
,
S.
,
Schatz
,
T.
,
Howard
,
S.
, and
Smith
,
M. E.
,
2016
, “
Thrombogenicity Testing for Blood Contacting Medical Devices in an In Vitro Ovine Blood Loop
,”
ASME J. Med. Devices
,
10
(
2
), p.
020904
.
13.
Muller
,
H. R.
, and
Hinn
,
G.
,
1990
, “
Buser, Internal Jugular Venous Flow Measurement by Means of a Duplex Scanner
,”
J. Ultrasound Med.
,
9
(
5
), pp.
261
256
.
14.
Byrom
,
M. J.
,
Bannon
,
P. G.
,
White
,
G. H.
, and
Ng
,
M. K.
,
2010
, “
Animal Models for the Assessment of Novel Vascular Conduits
,”
J. Vasc. Surg.
,
52
(
1
), pp.
176
195
.
15.
Bianco
,
R. W.
,
Grehan
,
J. F.
,
Grubbs
,
B. C.
,
Mrachek
,
J. P.
,
Schroeder
,
E. L.
,
Schumacher
,
C. W.
,
Svendsen
,
C. A.
, and
Lahti
,
M.
,
2004
, “
Large Animal Models in Cardiac and Vascular Biomaterials Research and Testing
,”
Biomaterials Science: An Introduction to Materials in Medicine
, 2nd ed.,
B. D.
Ratner
,
A. S.
Hoffman
,
F. J.
Schoen
,
J. E.
Lemons
, eds.,
Academic Press
,
San Diego, CA
, pp.
379
395
.
16.
Pinto
,
D. S.
,
Lorenz
,
D. P.
,
Murphy
,
S. A.
,
Marble
,
S. J.
,
DiBattiste
,
P. M.
,
Demopoulos
,
L. A.
,
Cannon
,
C. P.
, and
Gibson
,
C. M.
,
2003
, “
TIMI Study Group. Association of an Activated Clotting Time < or =250 Seconds With Adverse Event Rates After Percutaneous Coronary Intervention Using Tirofiban and Heparin (A TACTICS-TIMI 18 Substudy)
,”
Am. J. Cardiol.
,
91
(
8
), pp.
976
978
.
17.
St. Jude Medical
,
2016
, “
St. Jude Medical Complaint Handling Database; Search Performed for Thromboembolic Events for the St. Jude Medical™ Response™ Electrophysiology Catheter May 2011–April 2016
,” St. Jude Medical Data Analytics, St. Paul, MN, Internal Communication.
You do not currently have access to this content.