This paper presents a new method for estimating the tilt angles of endoscopic images. Disorientation is one of the major challenges during natural orifice translumenal endoscopic surgery (NOTES). Reorientation allows surgeons or gastroenterologists to work in off-axis conditions and provides an important reference for coupling a secondary image. Some published studies of angle estimation for NOTES still have the limitation under the influence of movement or vibration. This study proposes a new sensor-fusion method for reducing the shock-based error. A triaxial accelerometer measures the gravitational vector (g-components) in all static states. When motion appears, the angular velocity from a triaxial gyroscope is used to calculate the elemental changes in g-components. A so-called predict-and-choose process relies on this data to predict the future state by giving many prediction values. The relationship between these values, the newest accelerometer readings, and their variation determine the final choice. Hence, under all conditions, the gravitational components are iteratively estimated to calculate the tilt angles. The result is evaluated by being applied in a well-known application, endoscopic horizon stabilization. Compared with the reference method, the proposed method has notable advantages. The simulation and experimental results show small errors, smooth angle change, and a small delay time. The tilt angles are reliable without any cumulative error under the prolonged motion. Therefore, this study gives surgeons or gastroenterologists an improved rectified image for reorienting under off-axis conditions. Further research will identify more applications for the development of surgical instruments for NOTES.

References

1.
Dray
,
X.
, and
Kalloo
,
A. N.
,
2012
, “
History of NOTES
,”
Natural Orifice Translumenal Endoscopic Surgery: Textbook and Video Atlas
, 1st ed.,
A. N.
Kalloo
,
J.
Marescaux
, and
R.
Zorron
, eds.,
Wiley-Blackwell
,
Hoboken
,
NJ
, pp.
3
11
.
2.
McGee
,
M. F.
,
Rosen
,
M. J.
,
Marks
,
J.
,
Onders
,
R. P.
,
Chak
,
A.
,
Faulx
,
A.
,
Chen
,
V. K.
, and
Ponsky
,
J.
,
2006
, “
A Primer on Natural Orifice Transluminal Endoscopic Surgery: Building a New Paradigm
,”
Surg. Innovation
,
13
(
2
), pp.
86
93
.
3.
Meadows
,
M. C.
, and
Chamberlain
,
R. S.
,
2010
, “
A Review on the Status of Natural Orifice Transluminal Endoscopic Surgery (NOTES) Cholecystectomy: Techniques and Challenges
,”
Open Access Surg.
,
2010
(
3
), pp.
73
86
.
4.
Rattner
,
D.
, and
Kalloo
,
A.
,
2006
, “
ASGE/SAGES Working Group on Natural Orifice Translumenal Endoscopic Surgery
,”
Surg. Endosc.
,
20
(
2
), pp.
329
333
.
5.
Höller
,
K.
,
Penne
,
J.
,
Schneider
,
A.
,
Jahn
,
J.
,
Guttiérrez
,
J.
,
Wittenberg
,
T.
,
Feußner
,
H.
, and
Hornegger
,
J.
,
2009
, “
Endoscopic Orientation Correction
,”
Medical Image Computing and Computer-Assisted Intervention—MICCAI
(Lecture Notes in Computer Science), Vol.
5761
,
Springer
,
Berlin
, pp.
459
466
.
6.
Höller
,
K.
,
Penne
,
J.
,
Hornegger
,
J.
,
Schneider
,
A.
,
Gillen
,
S.
,
Feußner
,
H.
,
Jahn
,
J.
,
Guttiérrez
,
J.
, and
Wittenberg
,
T.
,
2009
, “
Clinical Evaluation of Endorientation: Gravity Related Rectification for Endoscopic Images
,”
6th International Symposium on Image and Signal Processing and Analysis
(
ISPA 2009
), Salzburg, Austria, Sept. 16–18, pp.
713
717
.
7.
Höller
,
K.
,
Penne
,
J.
,
Schneider
,
A.
,
Jahn
,
J.
,
Girgis
,
H.
,
Guttiérrez
,
J.
,
Wittenberg
,
T.
,
Feußner
,
H.
, and
Hornegger
,
J.
,
2009
, “
Suppression of Shock Based Errors With Gravity Related Endoscopic Image Rectification
,”
5th Russian-Bavarian Conference on Bio-Medical Engineering
(
RBC'™09
),
Munich
,
Germany
, July 1–4, pp.
43
47
.
8.
Warren
,
A.
,
Mountney
,
P.
,
Noonan
,
D.
, and
Yang
,
G.-Z.
,
2012
, “
Horizon Stabilized—Dynamic View Expansion for Robotic Assisted Surgery (HS-DVE)
,”
Int. J. Comput. Assisted Radiol. Surg.
,
7
(
2
), pp.
281
288
.
9.
Luinge
,
H. J.
, and
Veltink
,
P. H.
,
2004
, “
Inclination Measurement of Human Movement Using a 3-D Accelerometer With Autocalibration
,”
IEEE Trans. Neural Syst. Rehabil. Eng.
,
12
(
1
), pp.
112
121
.
10.
Luinge
,
H. J.
, and
Veltink
,
P. H.
,
2005
, “
Measuring Orientation of Human Body Segments Using Miniature Gyroscopes and Accelerometers
,”
Med. Biol. Eng. Comput.
,
43
(
2
), pp.
273
282
.
11.
Dejnabadi
,
H.
,
Jolles
,
B. M.
, and
Aminian
,
K.
,
2005
, “
A New Approach to Accurate Measurement of Uniaxial Joint Angles Based on a Combination of Accelerometers and Gyroscopes
,”
IEEE Trans. Biomed. Eng.
,
52
(
8
), pp.
1478
1484
.
12.
Williamson
,
R.
, and
Andrews
,
B. J.
,
2001
, “
Detecting Absolute Human Knee Angle and Angular Velocity Using Accelerometers and Rate Gyroscopes
,”
Med. Biol. Eng. Comput.
,
39
(
3
), pp.
294
302
.
13.
Luinge
,
H. J.
,
Veltink
,
P. H.
, and
Baten
,
C. T. M.
,
1999
, “
Estimating Orientation With Gyroscopes and Accelerometers
,”
Technol. Health Care
,
7
(
6
), pp.
455
459
.
14.
Duke
,
E. L.
,
Antoniewicz
,
R. F.
, and
Krambeer
,
K. D.
,
1988
,
Derivation and Definition of a Linear Aircraft Model
(NASA Reference Publication), Vol.
1207
,
National Aeronautics and Space Administration (NASA)
,
Edwards, CA
.
15.
Pedley
,
M.
,
2013
, “
Tilt Sensing Using a Three-Axis Accelerometer
,”
Freescale Semiconductor
, Inc., Austin, TX, Application Note No. AN3461 Rev. 6.
16.
Diebel
,
J.
,
2006
, “
Representing Attitude: Euler Angles, Unit Quaternions, and Rotation Vectors
,” Stanford University, Stanford, CA.
17.
Looney
,
M.
,
2010
, “
A Simple Calibration for MEMS Gyroscopes
,” EDN Europe.
18.
Pedley
,
M.
,
2013
, “
High Precision Calibration of a Three-Axis Accelerometer
,”
Freescale Semiconductor
, Inc., Austin, TX, Application Note No. AN4399 Rev. 1.
19.
Sodergren
,
M. H.
,
Warren
,
A.
,
Nehme
,
J.
,
Clark
,
J.
,
Gillen
,
S.
,
Feussner
,
H.
,
Teare
,
J.
,
Darzi
,
A.
, and
Yang
,
G.-Z.
,
2014
, “
Endoscopic Horizon Stabilization in Natural Orifice Translumenal Endoscopic Surgery: A Randomized Controlled Trial
,”
Surg. Innovation
,
21
(
1
), pp.
74
79
.
20.
Rattner
,
D. W.
,
Hawes
,
R.
,
Schwaitzberg
,
S.
,
Kochman
,
M.
, and
Swanstrom
,
L.
,
2011
, “
The Second SAGES/ASGE White Paper on Natural Orifice Transluminal Endoscopic Surgery: 5 Years of Progress
,”
Surg. Endosc.
,
25
(
8
), pp.
2441
2448
.
21.
Lehman
,
A. C.
,
Dumpert
,
J.
,
Wood
,
N. A.
,
Redden
,
L.
,
Visty
,
A. Q.
,
Farritor
,
S.
,
Varnell
,
B.
, and
Oleynikov
,
D.
,
2009
, “
Natural Orifice Cholecystectomy Using a Miniature Robot
,”
Surg. Endosc.
,
23
(
2
), pp.
260
266
.
22.
Quaglia
,
C.
,
Petroni
,
G.
,
Niccolini
,
M.
,
Caccavaro
,
S.
,
Dario
,
P.
, and
Menciassi
,
A.
,
2014
, “
Design of a Compact Robotic Manipulator for Single-Port Laparoscopy
,”
ASME J. Mech. Des.
,
136
(
10
), p.
105001
.
You do not currently have access to this content.