This paper presents a new method for estimating the tilt angles of endoscopic images. Disorientation is one of the major challenges during natural orifice translumenal endoscopic surgery (NOTES). Reorientation allows surgeons or gastroenterologists to work in off-axis conditions and provides an important reference for coupling a secondary image. Some published studies of angle estimation for NOTES still have the limitation under the influence of movement or vibration. This study proposes a new sensor-fusion method for reducing the shock-based error. A triaxial accelerometer measures the gravitational vector (g-components) in all static states. When motion appears, the angular velocity from a triaxial gyroscope is used to calculate the elemental changes in g-components. A so-called predict-and-choose process relies on this data to predict the future state by giving many prediction values. The relationship between these values, the newest accelerometer readings, and their variation determine the final choice. Hence, under all conditions, the gravitational components are iteratively estimated to calculate the tilt angles. The result is evaluated by being applied in a well-known application, endoscopic horizon stabilization. Compared with the reference method, the proposed method has notable advantages. The simulation and experimental results show small errors, smooth angle change, and a small delay time. The tilt angles are reliable without any cumulative error under the prolonged motion. Therefore, this study gives surgeons or gastroenterologists an improved rectified image for reorienting under off-axis conditions. Further research will identify more applications for the development of surgical instruments for NOTES.
Skip Nav Destination
Article navigation
December 2016
Research-Article
Estimating Endoscopic Orientation in Static and Dynamic States With Inertial Sensors
Hung V. Dao,
Hung V. Dao
Graduate School of Engineering and Science,
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: nb13503@shibaura-it.ac.jp
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: nb13503@shibaura-it.ac.jp
Search for other works by this author on:
Takashi Komeda
Takashi Komeda
Professor
Bioscience and Engineering,
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: komeda@se.shibaura-it.ac.jp
Bioscience and Engineering,
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: komeda@se.shibaura-it.ac.jp
Search for other works by this author on:
Hung V. Dao
Graduate School of Engineering and Science,
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: nb13503@shibaura-it.ac.jp
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: nb13503@shibaura-it.ac.jp
Takashi Komeda
Professor
Bioscience and Engineering,
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: komeda@se.shibaura-it.ac.jp
Bioscience and Engineering,
Shibaura Institute of Technology,
Saitama City,
Saitama 337-8570, Japan
e-mail: komeda@se.shibaura-it.ac.jp
Manuscript received September 17, 2015; final manuscript received March 14, 2016; published online August 5, 2016. Assoc. Editor: Carl Nelson.
J. Med. Devices. Dec 2016, 10(4): 041003 (7 pages)
Published Online: August 5, 2016
Article history
Received:
September 17, 2015
Revised:
March 14, 2016
Citation
Dao, H. V., and Komeda, T. (August 5, 2016). "Estimating Endoscopic Orientation in Static and Dynamic States With Inertial Sensors." ASME. J. Med. Devices. December 2016; 10(4): 041003. https://doi.org/10.1115/1.4033332
Download citation file:
69
Views
Get Email Alerts
Cited By
Related Articles
Data Communication Pathway for Sensing Guidewire at Proximal Side: A Review
J. Med. Devices (June,2017)
Hydraulic Robotic Surgical Tool Changing Manipulator
J. Med. Devices (March,2017)
Design and Preliminary Evaluation of a Stiff Steerable Cutter for Arthroscopic Procedures
J. Med. Devices (December,2015)
Endoscopic Closure of Large Defects With a Novel Clipping Device and a 4S-Modified Roeder Slipknot
J. Med. Devices (June,2018)
Related Proceedings Papers
Related Chapters
Key Technology of Interactive Music Game Installation based on Arduino
International Conference on Control Engineering and Mechanical Design (CEMD 2017)
Modeling and Realization on a Chip of Growth Hormone Secretion Mechanism
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Design and Analysis of a Double-Half-Revolution Mechanism Exploration Rover
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)