This paper provides an experimental and numerical investigation of natural convection in a square cavity. The square cavity is full of air (Pr = 0.71) and contains four heat sources of height hW, positioned symmetrically on the vertical walls of the cavity with a fifth heat source of height hB, located in the center of the bottom cavity wall. Two configurations are analyzed for Rayleigh numbers ranging from 1.00 × 104 to 1.00 × 105: configuration 1 has four cold sources located on the vertical cavity wall and configuration 2 has two hot and two cold sources located on the vertical cavity walls. An analysis of the holographic interferograms, numerical isotherms, streamlines, and velocity maps obtained demonstrates an increased development of natural convective heat transfer in configuration 1.

References

1.
Chu
,
H. S. S.
,
Churchill
,
S. W.
, and
Patterson
,
S. V.
,
1976
, “
The Effects of Heater Size, Location, Aspect Ratio, and Boundary Conditions on Two-Dimensional, Laminar, Natural Convection in Rectangular Channels
,”
ASME J. Heat Transfer
,
98
(
2
), pp.
194
201
.
2.
Türkoglu
,
H.
, and
Yücel
,
N.
,
1995
, “
Effects of Heater and Cooler Location on Natural Convection in Square Cavities
,”
Numer. Heat Transfer, Part A
,
27
(
3
), pp.
351
358
.
3.
Valencia
,
A.
, and
Frederick
,
R. L.
,
1989
, “
Heat Transfer in Square Cavities With Partially Active Vertical Walls
,”
Int. J. Heat Mass Transfer
,
32
(
8
), pp.
1567
1574
.
4.
Zhao
,
F. H.
,
Liu
,
D.
, and
Tang
,
G. F.
,
2007
, “
Resonant Response of Fluid Flow Subjected to Discrete Heating Elements
,”
Energy Convers. Manage.
,
48
(
9
), pp.
2461
2472
.
5.
Deng
,
Q. H.
,
2008
, “
Fluid Flow and Heat Transfer Characteristics of Natural Convection in Square Cavities Due to Discrete Source-Sink Pairs Positions
,”
Int. J. Heat Mass Transfer
,
51
(25–26), pp.
5949
5957
.
6.
Cheikh
,
N. B.
,
Beya
,
B. B.
, and
Lili
,
T.
,
2007
, “
Influence of Thermal Boundary Conditions on Natural Convection in a Square Enclosure Partially Heated From Below
,”
Int. Commun. Heat Mass Transfer
,
34
(
3
), pp.
369
379
.
7.
Zaman
,
F. S.
,
Turja
,
T. S.
, and
Molla
,
Md. M.
,
2013
, “
Buoyancy Driven Natural Convection Flow in an Enclosure With Two Discrete Heating From Below
,”
Procedia Eng.
,
56
, pp.
104
111
.
8.
Chen
,
T. H.
, and
Chen
,
L. Y.
,
2007
, “
Study of Buoyancy-Induced Flows Subjected to Partially Heated Sources on the Left and Bottom Walls in a Square Enclosure
,”
Int. J. Therm. Sci.
,
46
(
12
), pp.
1219
1231
.
9.
Sharif
,
M. A. R.
, and
Mohammad
,
T. R.
,
2005
, “
Natural Convection in Cavities With Constant Flux Heating at the Bottom Wall and Isothermal Cooling From the Sidewalls
,”
Int. J. Therm. Sci.
,
44
(
9
), pp.
865
878
.
10.
Sezai
,
I.
, and
Mohamad
,
A. A.
,
2000
, “
Natural Convection in a Rectangular Cavity Heated From Below and Cooled From Top as Well as the Sides
,”
Phys. Fluids
,
12
(
9
), pp.
2210
2223
.
11.
Frederick
,
R. L.
, and
Quiroz
,
F.
,
2001
, “
On the Transition From Conduction to Convection Regime in a Cubical Enclosure With a Partially Heated Wall
,”
Int. J. Heat Mass Transfer
,
44
(
9
), pp.
1699
1709
.
12.
Ho
,
C. J.
, and
Chang
,
J. Y.
,
1994
, “
A Study of Natural Convection Heat Transfer in a Vertical Rectangular Enclosure With Two-Dimensional Discrete Heating: Effect of Aspect Ratio
,”
Int. J. Heat Mass Transfer
,
37
(
6
), pp.
917
925
.
13.
Nithyadevi
,
N.
,
Kandaswamy
,
N. P.
, and
Lee
,
J.
,
2007
, “
Natural Convection in a Rectangular Cavity With Partially Active Side Walls
,”
Int. J. Heat Mass Transfer
,
50
(23–24), pp.
4688
4697
.
14.
Baïri
,
A.
,
de Maria
,
J. M. G.
,
Baïri
,
I.
,
Laraqi
,
N.
,
Zarco-Pernia
,
E.
, and
Alilat
,
N.
,
2012
, “
2D Transient Natural Convection in Diode Cavities Containing an Electronic Equipment With Discrete Active Bands Under Constant Heat Flux
,”
Int. J. Heat Mass Transfer
,
55
(19–20), pp.
4970
4980
.
15.
Nardini
,
G.
, and
Paroncini
,
M.
,
2012
, “
Heat Transfer Experiment on Natural Convection in a Square Cavity With Discrete Sources
,”
Heat Mass Transfer
,
48
(
11
), pp.
1855
1865
.
16.
Hauf
,
W.
, and
Grigull
,
U.
,
1970
, “
Optical Methods in Heat Transfer
,”
Advances in Heat Transfer
,
J. P.
Harnett
, and
T. F.
Irvine
, Jr.
, eds.,
Academic Press
,
New York
, pp.
133
311
.
17.
ANSYS
,
2009
, “
Fluent User's Guide, Release 12.0
,” ANSYS, Inc., Canonsburg, PA.
18.
Valencia
,
A.
, and
Fredrick
,
R. L.
,
1989
, “
Heat Transfer in Square Cavities With Partially Active Vertical Walls
,”
Int. J. Heat Mass Transfer
,
32
(
8
), pp.
1567
1574
.
19.
Kakaçs
,
S.
,
Aung
,
W.
, and
Viskanta
,
R.
,
1985
,
Natural Convection: Fundamentals and Applications
,
Hemisphere Publishing Corporation
,
Washington, DC
.
20.
Rawlings
,
J. O.
,
Pantula
,
S. G.
, and
Dickey
,
D. A.
,
1998
,
Applied Regression Analysis: A Research Tool
, 2nd ed.,
Springer
,
New York
.
You do not currently have access to this content.