A simple use of Venturi might be used to measure two-phase flow rate within relatively low GVF(gas volume fraction). Upstream flow entering Venturi can be improved with installed flow homogenizer which is easily fabricated by 3-dimensional printer with multiple holes. Simultaneous measurement between high-speed flow visualization and dynamic differential pressure measurement was made to find visual criteria for two-phase flow rate measurement with different GVF ranged from 0% to 30%. It was observed that the two-phase flow rate can be reliably measured up to 15% of GVF using flow homogenizer. FFT(Fast-Fourier Transform) results proved that the long flow homogenizers (type 2 and 4) showed a lower amplitude of differential pressure (Δp) than the short flow homogenizers (type 1 and 3) respectively. So the optimized flow homogenizer can be useful to measure two-phase flow rate at low GVF.
Skip Nav Destination
Article navigation
Photo Gallery
Visual Criteria for Measuring Two-phase Flow Rate in Venturi with Flow Homogenizer
Sangho Sohn,
Sangho Sohn
Department of Extreme Thermal Systems,
sangho@kimm.re.kr
Korea Institute of Machinery and Materials
, Daejon,305-343
, Korea
sangho@kimm.re.kr
Search for other works by this author on:
Jaebum Park,
Jaebum Park
Department of Extreme Thermal Systems,
johnpaulpark@kimm.re.kr
Korea Institute of Machinery and Materials
, Daejon,305-343
, Korea
johnpaulpark@kimm.re.kr
Search for other works by this author on:
Dong-Wook Oh
Dong-Wook Oh
Search for other works by this author on:
Sangho Sohn
Department of Extreme Thermal Systems,
sangho@kimm.re.kr
Korea Institute of Machinery and Materials
, Daejon,305-343
, Korea
sangho@kimm.re.kr
Jaebum Park
Department of Extreme Thermal Systems,
johnpaulpark@kimm.re.kr
Korea Institute of Machinery and Materials
, Daejon,305-343
, Korea
johnpaulpark@kimm.re.kr
Dong-Wook Oh
Corresponding author.
J. Heat Transfer. Aug 2015, 137(8): 080911
Published Online: August 1, 2015
Article history
Received:
March 30, 2015
Revised:
April 3, 2015
Online:
June 1, 2015
Citation
Sohn, S., Park, J., and Oh, D. (August 1, 2015). "Visual Criteria for Measuring Two-phase Flow Rate in Venturi with Flow Homogenizer." ASME. J. Heat Transfer. August 2015; 137(8): 080911. https://doi.org/10.1115/1.4030475
Download citation file:
60
Views
Get Email Alerts
Cited By
Annulus-side flow boiling and visualization of a three-dimensionally enhanced tube
J. Heat Mass Transfer
Related Articles
Two-Phase Dusty Fluid Flow Along a Rotating Axisymmetric Round-Nosed Body
J. Heat Transfer (August,2017)
Computational Fluid Dynamics Modeling of Two-Phase Flow in an Adiabatic Capillary Tube
J. Thermal Sci. Eng. Appl (March,2015)
Experimental Investigation and Empirical Correlations of Heat Transfer in Different Regimes of Air–Water Two-Phase Flow in a Horizontal Tube
J. Thermal Sci. Eng. Appl (June,2017)
Heat Transfer Photogallery
J. Heat Transfer (February,2017)
Related Chapters
Applications
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
A Simple Carburetor
Case Studies in Fluid Mechanics with Sensitivities to Governing Variables
Liquid Cooled Systems
Thermal Management of Telecommunications Equipment