This work presents an experimental geometric optimization study to maximize the total heat transfer rate between a bundle of finned tubes in a given volume and a given external flow both for circular and elliptic arrangements, for general staggered configurations. The results are reported for air as the external fluid, in the range 2650Re2b10,600, where 2b is the smaller ellipse axis. Experimental optimization results for finned circular and elliptic tubes arrangements are presented. A relative heat transfer gain of up to 80% (Re2b=10,600) is observed in the elliptic arrangement optimized with respect to tube-to-tube spacings, as compared to the optimal circular one. A relative heat transfer gain of 80% is observed in the three-way optimized elliptic arrangement in comparison with the two-way optimized circular one; i.e., with respect to tube-to-tube and fin-to-fin spacings. An empirical correlation for the three-way optimized configuration was obtained to evaluate the resulting maximized dimensionless heat transfer rate.

1.
Bordalo
,
S. N.
, and
Saboya
,
F. E. M.
, 1999, “
Pressure Drop Coefficients for Elliptic and Circular Sections in One, Two and Three-Row Arrangements of Plate Fin and Tube Heat Exchangers
,”
J. Braz. Soc. Mech. Sci.
0100-7386,
21
(
4
) pp.
600
610
.
2.
Saboya
,
S. M.
, and
Saboya
,
F. E. M.
, 2001, “
Experiments on Elliptic Sections in One and Two-Row Arrangements of Plate Fin and Tube Heat Exchangers
,”
Exp. Therm. Fluid Sci.
0894-1777,
24
(
1–2
), pp.
67
75
.
3.
Rosman
,
E. C.
,
Carajilescov
,
P.
, and
Saboya
,
F. E. M.
, 1984, “
Performance of One and Two-Row Tube and Plate Fin Heat Exchangers
,”
ASME J. Heat Transfer
0022-1481,
106
(
3
), pp.
627
632
.
4.
Khan
,
M. G.
,
Fartaj
,
A.
, and
Ting
,
D. S. K.
, 2004, “
An Experimental Characterization of Cross-Flow Cooling of Air via an In-Line Elliptical Tube Array
,”
Int. J. Heat Fluid Flow
0142-727X,
25
(
4
), pp.
636
648
.
5.
Elshazly
,
K.
,
Moawed
,
M.
,
Ibrahim
,
E.
, and
Emara
,
M.
, 2005, “
Heat Transfer by Free Convection from the Inside Surface of the Vertical and Inclined Elliptic Tube
,”
Energy Convers. Manage.
0196-8904,
46
(9–10), pp.
1443
1463
.
6.
Elsayed
,
A. O.
,
Ibrahim
,
E. Z.
, and
Elsayed
,
S. A.
, 2003, “
Free Convection from a Constant Heat Flux Elliptic Tube
,”
Energy Convers. Manage.
0196-8904,
44
(
15
), pp.
2445
2453
.
7.
Min
,
J. C.
, and
Webb
,
R. L.
, 2004, “
Numerical Analyses of Effects of Tube Shape on Performance of a Finned Tube Heat Exchanger
,”
J. Enhanced Heat Transfer
1065-5131,
11
(
1
), pp.
61
73
.
8.
Kundu
,
B.
,
Maiti
,
B.
, and
Das
,
P. K.
, 2006, “
Performance Analysis of Plate Fins Circumscribing Elliptic Tubes
,”
Heat Transfer Eng.
0145-7632,
27
(
3
), pp.
86
94
.
9.
O’Brien
,
J. E.
, and
Sohal
,
M. S.
, 2005, “
Heat Transfer Enhancement for Finned-Tube Heat Exchangers With Winglets
,”
ASME J. Heat Transfer
0022-1481,
127
(
2
), pp.
171
178
.
10.
O’Brien
,
J. E.
,
Sohal
,
M. S.
, and
Wallstedt
,
P. C.
, 2004, “
Local Heat Transfer and Pressure Drop for Finned-Tube Heat Exchangers Using Oval Tubes and Vortex Generators
,”
ASME J. Heat Transfer
0022-1481,
126
(
5
), pp.
826
835
.
11.
Gao
,
S. D.
,
Wang
,
L. B.
,
Zhang
,
Y. H.
, and
Ke
,
F.
, 2003, “
The Optimum Height of Winglet Vortex Generators Mounted on Three-row Flat Tube Bank Fin
,”
ASME J. Heat Transfer
0022-1481,
125
(
6
), pp.
1007
1016
.
12.
Kim
,
N. H.
,
Youn
,
B.
, and
Webb
,
R. L.
, 1999, “
Air-Side Float Transfer and Friction Correlations for Plain Fin-and-Tube Heat Exchangers With Staggered Tube Arrangements
,”
ASME J. Heat Transfer
0022-1481,
121
(
3
), pp.
662
667
.
13.
Bejan
,
A.
, 2000,
Shape and Structure, From Engineering to Nature
,
Cambridge University Press
,
Cambridge, UK
.
14.
Matos
,
R. S.
,
Vargas
,
J. V. C.
,
Laursen
,
T. A.
, and
Saboya
,
F. E. M.
, 2001, “
Optimization Study and Heat Transfer Comparison of Staggered Circular and Elliptic Tubes in Forced Convection
,”
Int. J. Heat Mass Transfer
0017-9310,
44
(
20
), pp.
3953
3961
.
15.
Matos
,
R. S.
,
Vargas
,
J. V. C.
,
Laursen
,
T. A.
, and
Bejan
,
A.
, 2004, “
Optimally Staggered Finned Circular and Elliptic Tubes in Forced Convection
,”
Int. J. Heat Mass Transfer
0017-9310,
47
(
6–7
), pp.
1347
1359
.
16.
Matos
,
R. S.
,
Laursen
,
T. A.
,
Vargas
,
J. V. C.
, and
Bejan
,
A.
, 2004, “
Three-Dimensional Optimization of Staggered Finned Circular and Elliptic Tubes in Forced Convection
,”
Int. J. Therm. Sci.
1290-0729,
43
(
5
), pp.
477
487
.
17.
Editorial, 1993, “
Journal of Heat Transfer Policy on Reporting Uncertainties in Experimental Measurements and Results
,”
ASME J. Heat Transfer
0022-1481,
115
, pp.
5
6
.
You do not currently have access to this content.