Upward motion of a balcony spill plume in an atrium with a thermal stratified layer will be simulated. This is aimed at answering the question on whether a smoke plume can move up an atrium to reach the ceiling. The gradient of air density in the atrium is taken as a constant negative value. The plume motion under this condition is compared with the case without a thermal stratified layer. It is noted that the effect of stratification is not obvious in regions near to the fire. But for the upper region of the plume, the effect is significant. In this way, the plume might not be able to reach the ceiling of an atrium with a hot enough thermal stratified layer. The maximum plume rise under this condition will also be calculated.
Issue Section:
Natural and Mixed Convection
Keywords:
smoke,
flow simulation,
stratified flow,
density,
Enclosure Flows,
Entrainment,
Fire,
Heat Transfer,
Plumes,
Stratified
1.
Thomas
, P. H.
, 1987
, “On the Upward Movement of Smoke and Related Shopping Mall Problems
,” Fire Saf. J.
, 12
, pp. 191
–203
.2.
Law
, M.
, 1986
, “A Note on Smoke Plumes from Fires in Multi-Level Shopping Malls
,” Fire Saf. J.
, 10
, pp. 197
–202
.3.
Law
, M.
, 1995
, “Measurements of Balcony Smoke Flow
,” Fire Saf. J.
, 24
, pp. 189
–195
.4.
Morgan, H. P., and Marshall, N. R., 1975, “Smoke Hazards in Covered Multi-Level Shopping Malls: An Experimentally Based Theory for Smoke Production,” Building Research Establishment Current Paper CP48/75, Building Research Establishment, Garston, UK.
5.
Hansell, G. O., Morgan, H. P., and Marshall, N. R., 1993, “Smoke Flow Experiments in a Model Atrium,” Building Research Establishment Occasional Paper OP55, Building Research Establishment, Garston, UK.
6.
Marshall, N. R., and Harrison, R., 1996, “Experimental Studies of the Thermal Spill Plumes,” Building Research Establishment Occasional Paper OP1, Building Research Establishment, Garston, UK.
7.
Thomas
, P. H.
, Morgan
, H. P.
, and Marshall
, N.
, 1998
, “The Spill Plume in Smoke Control Design
,” Fire Saf. J.
, 30
, pp. 21
–46
.8.
Poreh
, M.
, Morgan
, H. P.
, Marshall
, N. R.
, and Harrison
, R.
, 1998
, “Entrainment by Two-Dimensional Spill Plumes
,” Fire Saf. J.
, 30
, pp. 1
–19
.9.
Lee
, L.
, and Emmons
, H. W.
, 1961
, “A Study of Natural Convection above Line Fires
,” J. Fluid Mech.
, 11
, pp. 353
–368
.10.
Chow
, W. K.
, and Cui
, E.
, 1998
, “CFD Simulations on Balcony Spill Plume
,” J. Fire Sci.
, 16
(6
), pp. 468
–485
.11.
Miles, S., Kumar, S., and Cox, G., 1997, “The Balcony Spill Plume—Some CFD Simulations,” Fire Safety Science—Proceedings of the Fifth International Symposium, International Association for Fire Safety Science, Melbourne, pp. 237–247.
12.
Hansell, G. O., and Morgan, H. P., 1994, “Design Approaches for Smoke Control in Atrium Buildings,” Building Research Establishment Report BR258, Building Research Establishment, Garston, UK.
13.
Morgan, H. P., Ghosh, B. K., and Garrad, G., 1999, “Design Methodologies for Smoke and Heat Exhaust Ventilation,” Building Research Establishment Report BR368, Building Research Establishment, Garston, UK.
14.
NFPA 92B, 1995, “Guide for Smoke Management Systems in Malls, Atria and Large Areas,” (design guide), National Fire Protection Association, Quincy, MA, USA.
15.
Klote, J. H., “Method of Predicting Smoke Movement in Atria with Application to Smoke Management,” NISTIR 5516, National Institute of Standards and Technology, Gaithersburg, MD.
16.
Klote
, J. H.
, 2000
, “New Development in Atrium Smoke Management
,” ASHRAE Trans.
, 106, Part I
, pp. 620
–626
.17.
Morton
, B. R.
, Taylor
, G. I.
, and Turner
, J. S.
, 1956
, “Turbulent Gravitational Convection from Maintained and Instantaneous Sources
,” Proc. R. Soc. London, Ser. A
, A234
, pp. 1
–23
.18.
Morton
, B. R.
, 1959
, “Forced Plumes
,” J. Fluid Mech.
, 5
, pp. 151
–163
.19.
Turner, J. S., 1973, Buoyancy Effects in Fluids, Cambridge University Press, London, UK.
20.
Heskestad
, G.
, 1989
, “Note on Maximum Rise of Fire Plumes in Temperature-Stratified Ambients
,” Fire Saf. J.
, 15
, pp. 271
–276
.21.
Bloomfield
, L. J.
, and Kerr
, R. C.
, 1998
, “Turbulent Fountains in Stratified Fluid
,” J. Fluid Mech.
, 358
, pp. 335
–356
.22.
Cardoso
, S. S. S.
, and Woods
, A. W.
, 1993
, “Mixing by a Turbulent Plume in a Confined Stratified Region
,” J. Fluid Mech.
, 250
, pp. 277
–305
.23.
The PHOENICS 3.2 POLIS, 1998, CHAM Ltd., Wimbledon Village, London, UK.
24.
Chow
, W. K.
, Li
, Y. Z.
, Cui
, E.
, and Huo
, R.
, 2001
, “Natural Smoke Filling in Atrium with Liquid Pool Fires up to 1.6 MW
,” Build. Environ.
, 36
(1
), pp. 121
–127
.25.
Batchelor
, G. K.
, 1954
, “Heat Convection and Buoyancy Effects in Fluids
,” Quart. J. Roy. Met. Soc.
, 80
, pp. 339
–358
.26.
Rouse
, H.
, Yih
, C. S.
, and Humphreys
, H. W.
, 1952
, “Gravitational Convection from a Boundary Source
,” Tellus
, 4
, pp. 201
–210
.27.
Yuan
, L. M.
, and Cox
, G.
, 1996
, “An Experiment Study of Some Line Fires
,” Fire Saf. J.
, 27
, pp. 123
–139
.28.
Chen, C. J., and Rodi, W., 1975, “A Review of Experimental Data of Vertical Turbulent Buoyant Jets,” University of Karlsruhe Report SFB 80/T/69.
29.
Yokoi, S., 1960, “Study on the Prevention of Fire Spread Caused by Hot Upward Current,” Building Research Report 34, Japanese Ministry of Construction.
30.
Rodi, W., 1984, Turbulence Models and Their Application in Hydraulics, second revised edition, IAHR, Netherlands, pp. 9–46.
31.
Markatos
, N. C.
, Malin
, M. R.
, and Cox
, G.
, 1982
, “Mathematical Modelling of Buoyancy-Induced Smoke Flow in Enclosures
,” Int. J. Heat Mass Transf.
, 25
(1
), pp. 63
–75
.32.
Xue
, H.
, Ho
, J. C.
, and Cheng
, Y. M.
, 2001
, “Comparison of Different Combustion Models in Enclosure Fire Simulation
,” Fire Saf. J.
, 36
, pp. 37
–54
.33.
Chow
, W. K.
, 1995
, “Use of Computational Fluid Dynamics for Simulating Enclosure Fires
,” J. Fire Sci.
, 13
, pp. 300
–333
.34.
Nam
, S.
, and Bill
, R. G.
, 1993
, “Numerical Simulation of Thermal Plumes
,” Fire Saf. J.
, 21
(3
), pp. 231
–256
.35.
Chow
, W. K.
, 1995
, “Use of Computational Fluid Dynamics for Simulating Enclosure Fires
,” J. Fire Sci.
, 13
, pp. 300
–333
.36.
Chow
, W. K.
, 1995
, “A Comparison of the Use of Fire Zone and Field Models for Simulating Atrium Smoke-filling Process
,” Fire Saf. J.
, 25
, pp. 337
–353
.37.
Yang
, K. T.
, 1994
, “Recent Development in Field Modelling of Compartment Fires
,” JSME Int. J., Ser. B
, 37
(4
), pp. 702
–717
.Copyright © 2003
by ASME
You do not currently have access to this content.