Natural convection from a heated disk situated at the bottom of a top-vented enclosure was studied experimentally. The experiments were performed in water (Pr ≅ 5) for parametric variations of the vent opening size, inner enclosure height, and disk-to-enclosure-wall tempearture difference (Rayleigh number). For comparison purposes, baseline data were obtained for an unvented enclosure and for the “infinite” case (no enclosure). The heat transfer data were supplemented by cross-vent temperature measurements and by flow visualization using the thymol-blue electrochemical technique. The experiments demonstrated that, for the range of parameters considered, the average Nusselt numbers could be correlated using a single correlation to within 8 percent. It was also found that the presence of the enclosure (vented or unvented) acted to reduce the Nusselt number, especially at the lower Rayleigh numbers. Flow visualization experiments revealed an unstable flow pattern in the vicinity of the vent that fluctuated in a nonperiodic manner between four basic modes. Temperature measurements revealed asymmetric mean cross-vent temperature profiles, with the mean temperature level increasing with decreasing vent size. The intensity of the temperature fluctuations in the vent opening also increased with decreasing vent size.
Skip Nav Destination
Article navigation
Research Papers
Natural Convection From a Heat Source in a Top-Vented Enclosure
T. A. Myrum
T. A. Myrum
Mechanical Engineering Department, Louisiana State University, Baton Rouge, LA 70803
Search for other works by this author on:
T. A. Myrum
Mechanical Engineering Department, Louisiana State University, Baton Rouge, LA 70803
J. Heat Transfer. Aug 1990, 112(3): 632-639 (8 pages)
Published Online: August 1, 1990
Article history
Received:
February 13, 1989
Revised:
November 22, 1989
Online:
May 23, 2008
Citation
Myrum, T. A. (August 1, 1990). "Natural Convection From a Heat Source in a Top-Vented Enclosure." ASME. J. Heat Transfer. August 1990; 112(3): 632–639. https://doi.org/10.1115/1.2910434
Download citation file:
Get Email Alerts
Cited By
Annulus-side flow boiling and visualization of a three-dimensionally enhanced tube
J. Heat Mass Transfer
Study on the Influence of Different Momentum Ratios on Cold and Hot Fluid Mixing and Thermal Stress in T-Tube
J. Heat Mass Transfer (July 2025)
Related Articles
Oscillatory Natural Convection in Rectangular Enclosures Filled With Mercury
J. Heat Transfer (February,1990)
The First Instability Mechanism in Differentially Heated Cavities With Conducting Horizontal Walls
J. Heat Transfer (August,1995)
A Note on Multiple and Unsteady Solutions in Two-Dimensional Convection in a Tall Cavity
J. Heat Transfer (November,1990)
Rayleigh-Be´nard Convection in a Small Aspect Ratio Enclosure: Part I—Bifurcation to Oscillatory Convection
J. Heat Transfer (May,1993)
Related Proceedings Papers
Related Chapters
Finite Element Solution of Natural Convection Flow of a Nanofluid along a Vertical Flat Plate with Streamwise Sinusoidal Surface Temperature
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)
Applications
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Heating a Room by Natural Convection
Case Studies in Fluid Mechanics with Sensitivities to Governing Variables