The design of flashback-resistant premixed burners for hydrogen-rich fuels is strongly dependent on reliable turbulent boundary layer flashback limits, since this process can be the dominant failure type for mixtures with high burning velocities. So far, the flashback data published in literature is based on tube burner experiments with unconfined flames. However, this flame configuration may not be representative for the most critical design case, which is a flame being already present inside the duct geometry. In order to shed light on this potential misconception, boundary layer flashback limits have been measured for unconfined and confined flames in fully premixed hydrogen-air mixtures at atmospheric conditions. Two duct geometries were considered, a tube burner and a quasi-2D turbulent channel flow. Furthermore, two confined flame holding configurations were realized, a small backward-facing step inside the duct and a ceramic tile at high temperature, which was mounted flush with the duct wall. While the measured flashback limits for unconfined tube burner flames compare well with literature results, a confinement of the stable flame leads to a shift of the flashback limits towards higher critical velocity gradients, which are in good agreement between the tube burner and the quasi-2D channel setup. The underestimation of flashback propensity resulting from unconfined tube burner experiments emerges from the physical situation at the burner rim. Heat loss from the flame to the wall results in a quenching gap, which causes a radial leakage flow of fresh gases. This flow in turn tends to increase the quenching distance, since it constitutes an additional convective heat loss. On the one hand, the quenching gap reduces the local adverse pressure gradient on the boundary layer. On the other hand, the flame base is pushed outward, which deters the flame from entering the boundary layer region inside the duct. The flashback limits of confined flames stabilized at backward-facing steps followed this interpretation, and experiments with a flush ceramic flame holder constituted the upper limit of flashback propensity. It is concluded that the distribution of the flame backpressure and the flame position itself are key parameters for the determination of meaningful turbulent boundary layer flashback limits. For a conservative design path, the present results obtained from confined flames should be considered instead of unconfined tube burner values.
Skip Nav Destination
e-mail: eichler@td.mw.tum.de
Article navigation
January 2012
Research Papers
Experimental Investigation of Turbulent Boundary Layer Flashback Limits for Premixed Hydrogen-Air Flames Confined in Ducts
Christian Eichler,
Christian Eichler
Lehrstuhl für Thermodynamik,
e-mail: eichler@td.mw.tum.de
Technische Universität München
, Boltzmannstraße 15, 85748 Garching, Germany
Search for other works by this author on:
Georg Baumgartner,
Georg Baumgartner
Lehrstuhl für Thermodynamik,
Technische Universität München
, Boltzmannstraße 15, 85748 Garching, Germany
Search for other works by this author on:
Thomas Sattelmayer
Thomas Sattelmayer
Lehrstuhl für Thermodynamik,
Technische Universität München
, Boltzmannstraße 15, 85748 Garching, Germany
Search for other works by this author on:
Christian Eichler
Lehrstuhl für Thermodynamik,
Technische Universität München
, Boltzmannstraße 15, 85748 Garching, Germany
e-mail: eichler@td.mw.tum.de
Georg Baumgartner
Lehrstuhl für Thermodynamik,
Technische Universität München
, Boltzmannstraße 15, 85748 Garching, Germany
Thomas Sattelmayer
Lehrstuhl für Thermodynamik,
Technische Universität München
, Boltzmannstraße 15, 85748 Garching, Germany
J. Eng. Gas Turbines Power. Jan 2012, 134(1): 011502 (8 pages)
Published Online: November 4, 2011
Article history
Received:
April 13, 2011
Revised:
April 15, 2011
Online:
November 4, 2011
Published:
November 4, 2011
Citation
Eichler, C., Baumgartner, G., and Sattelmayer, T. (November 4, 2011). "Experimental Investigation of Turbulent Boundary Layer Flashback Limits for Premixed Hydrogen-Air Flames Confined in Ducts." ASME. J. Eng. Gas Turbines Power. January 2012; 134(1): 011502. https://doi.org/10.1115/1.4004149
Download citation file:
Get Email Alerts
Shape Optimization of an Industrial Aeroengine Combustor to reduce Thermoacoustic Instability
J. Eng. Gas Turbines Power
Dynamic Response of A Pivot-Mounted Squeeze Film Damper: Measurements and Predictions
J. Eng. Gas Turbines Power
Review of The Impact Of Hydrogen-Containing Fuels On Gas Turbine Hot-Section Materials
J. Eng. Gas Turbines Power
Effects of Lattice Orientation Angle On Tpms-Based Transpiration Cooling
J. Eng. Gas Turbines Power
Related Articles
Experiments on Flame Flashback in a Quasi-2D Turbulent Wall Boundary Layer for Premixed Methane-Hydrogen-Air Mixtures
J. Eng. Gas Turbines Power (January,2011)
Flashback Limits for Combustion Induced Vortex Breakdown in a Swirl Burner
J. Eng. Gas Turbines Power (July,2003)
Flashback in Lean Prevaporized Premixed Combustion: Nonswirling Turbulent Pipe Flow Study
J. Eng. Gas Turbines Power (July,2003)
Experimental Investigation of Turbulent Boundary Layer Flashback Limits for Premixed Hydrogen-Air Flames Confined in Ducts
Mechanical Engineering (December,2012)
Related Proceedings Papers
Related Chapters
The Identification of the Flame Combustion Stability by Combining Principal Component Analysis and BP Neural Network Techniques
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Numerical Modeling of N O x Emission in Turbulant Spray Flames Using Thermal and Fuel Models
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
A Collection of Handy Hydraulic Formulas Based on an Industry-Standard Reference for Pressure Drop Calculations, Incompressible Fluid Flow in Piping and Ducts—Crane Technical Paper No. 410
Hydraulics, Pipe Flow, Industrial HVAC & Utility Systems: Mister Mech Mentor, Vol. 1