The General Electric Company has developed and successfully tested a full-scale, F-class (2550°F combustor exit temperature), rich-quench-lean (RQL) gas turbine combustor, designated RQL2, for low heating value (LHV) fuel and integrated gasification combined cycle applications. Although the primary objective of this effort was to develop an RQL combustor with lower conversion of fuel bound nitrogen to NOx than a conventional gas turbine combustor, the RQL2 design can be readily adapted to natural gas and liquid fuel combustion. RQL2 is the culmination of a 5 year research and development effort that began with natural gas tests of a 2” diameter perforated plate combustor and included LHV fuel tests of RQL1, a reduced scale (6” diameter) gas turbine combustor. The RQL2 combustor includes a 14” diameter converging rich stage liner, an impingement cooled 7” diameter radially-stratified-quench stage, and a backward facing step at the entrance to a 10” diameter film cooled lean stage. The rich stage combustor liner has a novel double-walled structure with narrow circumferential cooling channels to maintain metal wall temperatures within design limits. Provisions were made to allow independent control of the air supplied to the rich and quench/lean stages. RQL2 has been fired for almost 100 hours with LHV fuel supplied by a pilot scale coal gasification and high temperature desulfurization system. At the optimum rich stage equivalence ration NOx emissions were about 50 ppmv (on a dry, 15 percent O2 basis), more than a factor of 3 lower than expected from a conventional diffusion flame combustor burning the same fuel. With 4600 ppmv NH3 in the LHV fuel, this corresponds to a conversion of NH3 to NOx of about 5 percent. As conditions were shifted away from the optimum, RQL2 NOx emissions gradually increased until they were comparable to a standard combustor. A chemical kinetic model of RQL2, constructed from a series of ideal chemical reactors, matched the measured NOx emissions fairly well. The CO emissions were between 5 and 30 ppmv (on a dry, 15 percent O2 basis) under all conditions.
Skip Nav Destination
Article navigation
July 1998
Research Papers
The GE Rich-Quench-Lean Gas Turbine Combustor
A. S. Feitelberg,
A. S. Feitelberg
GE Corporate Research and Development, One Research Circle, Niskayuna, NY 12309
Search for other works by this author on:
M. A. Lacey
M. A. Lacey
GE Corporate Research and Development, One Research Circle, Niskayuna, NY 12309
Search for other works by this author on:
A. S. Feitelberg
GE Corporate Research and Development, One Research Circle, Niskayuna, NY 12309
M. A. Lacey
GE Corporate Research and Development, One Research Circle, Niskayuna, NY 12309
J. Eng. Gas Turbines Power. Jul 1998, 120(3): 502-508 (7 pages)
Published Online: July 1, 1998
Article history
Received:
June 2, 1997
Online:
November 19, 2007
Citation
Feitelberg, A. S., and Lacey, M. A. (July 1, 1998). "The GE Rich-Quench-Lean Gas Turbine Combustor." ASME. J. Eng. Gas Turbines Power. July 1998; 120(3): 502–508. https://doi.org/10.1115/1.2818173
Download citation file:
Get Email Alerts
Heat Release Characteristics of a Volatile, Oxygenated, and Reactive Fuel in a Direct Injection Engine
J. Eng. Gas Turbines Power
Comprehensive Life Cycle Analysis of Diverse Hydrogen Production Routes and Application on a Hydrogen Engine
J. Eng. Gas Turbines Power
Related Articles
Topping Combustor Status for Second-Generation Pressurized Fluidized Bed Cycle Application
J. Eng. Gas Turbines Power (January,1997)
A Study on Low NO x Combustion in LBG-Fueled 1500°C-Class Gas Turbine
J. Eng. Gas Turbines Power (July,1996)
Effect of Pressure on Emission Characteristics in LBG-Fueled 1500°C-Class Gas Turbine
J. Eng. Gas Turbines Power (July,1998)
Gas Turbines Above 150 MW for Integrated Coal Gasification Combined Cycles (IGCC)
J. Eng. Gas Turbines Power (October,1992)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential