The fixed-geometry valve micropump is a seemingly simple device in which the interaction between mechanical, electrical, and fluidic components produces a maximum output near resonance. This type of pump offers advantages such as scalability, durability, and ease of fabrication in a variety of materials. Our past work focused on the development of a linear dynamic model for pump design based on maximizing resonance, while little has been done to improve valve shape. Here we present a method for optimizing valve shape using two-dimensional computational fluid dynamics in conjunction with an optimization procedure. A Tesla-type valve was optimized using a set of six independent, non-dimensional geometric design variables. The result was a 25% higher ratio of reverse to forward flow resistance (diodicity) averaged over the Reynolds number range 0<Re2000 compared to calculated values for an empirically designed, commonly used Tesla-type valve shape. The optimized shape was realized with no increase in forward flow resistance. A linear dynamic model, modified to include a number of effects that limit pump performance such as cavitation, was used to design pumps based on the new valve. Prototype plastic pumps were fabricated and tested. Steady-flow tests verified the predicted improvement in diodicity. More importantly, the modest increase in diodicity resulted in measured block-load pressure and no-load flow three times higher compared to an identical pump with non-optimized valves. The large performance increase observed demonstrated the importance of valve shape optimization in the overall design process for fixed-valve micropumps.

1.
Stemme
,
E.
, and
Stemme
,
G.
, 1993, “
A valveless diffuser∕nozzle-based fluid pump
,”
Sens. Actuators, A
0924-4247,
39
, pp.
159
167
.
2.
Gerlach
,
T.
, and
Wurmus
,
H.
, 1995, “
Working principle and performance of the dynamic micropump
,”
Sens. Actuators, A
0924-4247,
50
, pp.
135
140
.
3.
Forster
,
F.
,
Bardell
,
R.
,
Afromowitz
,
M.
, and
Sharma
,
N.
, 1995, “
Design, fabrication and testing of fixed-valve micropumps
,” in
Proceedings of the ASME Fluids Engineering Division 1995
,
San Francisco
,
D. C.
Wiggert
et al.
(Eds.), ASME, Vol.
FED-234
, pp.
39
44
.
4.
Jang
,
L.-S.
,
Morris
,
C. J.
,
Sharma
,
N. R.
,
Bardell
,
R. L.
, and
Forster
,
F. K.
, 1999, “
Transport of particle-laden fluids through fixed-valve micropumps
,” in
Micro-Electro-Mechanical Systems (MEMS)
, 1999 ASME International Mechanical Engineering Congress and Exposition,
A. P.
Lee
et al.
(Eds.), Vol.
MEMS-1
, pp.
503
509
.
5.
Jang
,
L.-S.
,
Sharma
,
N. R.
, and
Forster
,
F. K.
, 2000, “
The effect of particles on the performance of fixed-valve micropumps
,” in
Micro Total Analysis Systems 2000
,
A.
van den Berg
,
W.
Olthuis
, and
P.
Bergveld
(Eds.), pp.
283
286
.
6.
Morris
,
C. J.
, and
Forster
,
F. K.
, 2003, “
Low-order modeling of resonance for fixed-valve micropumps based on first principles
,”
J. Microelectromech. Syst.
1057-7157,
12
(
3
), pp.
325
334
.
7.
Williams
,
B. E.
, and
Forster
,
F. K.
, 2001, “
Micropump design for optimum pressure∕flow characteristics
,” in
Micro-Electro-Mechanical Systems (MEMS)
, ASME International Mechanical Engineering Congress and Exposition,
A. P.
Lee
(Ed.), ASME, Vol.
MEMS-3
, pp.
647
655
.
8.
Gamboa
,
A. R.
,
Morris
,
C. J.
, and
Forster
,
F. K.
, 2003, “
Optimized fixed-geometry valves for laminar flow micropumps
,” in
Proceedings of the ASME Fluids Engineering Division 2003
(Washington, DC), Vol.
FED-259
, pp.
525
534
.
9.
Morris
,
C. J.
, and
Forster
,
F. K.
, 2004, “
Oscillatory flow in microchannels: Comparison of exact and approximate imdedance models with experiment
,”
Exp. Fluids
0723-4864,
36
(
6
), pp.
928
937
.
10.
Tesla
,
N.
, 1920, “
Valvular Conduit
,” U.S. Patent No. 1,329,559.
11.
Groisman
,
A.
, and
Quake
,
S. R.
, 2004, “
A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers
,”
Phys. Rev. Lett.
0031-9007,
92
(
9
), pp.
094501
.
12.
Olsson
,
A.
,
Enoksson
,
P.
,
Stemme
,
G.
, and
Stemme
,
E.
, 1995, “
A Valve-less Planar Pump in Silicon
,” in
Transducers '95
(Stockholm), Vol.
2
, pp.
291
294
.
13.
Olsson
,
A.
,
Stemme
,
G.
, and
Stemme
,
E.
, 1999, “
Numerical Simulations of Flat-Walled Diffuser Elements for Valveless Micropumps
,” in
Proceedings of the Microsystems Modeling Conference
, pp.
585
588
.
14.
Forster
,
F. K.
, and
Williams
,
B. E.
, 2002, “
Parametric design of fixed-geometry microvalves—the Tesser valve
,” in
Proceedings of the ASME Fluids Engineering Division
, International Mechanical Engineering Congress and Exposition,
A.
Ogut
(Ed.), ASME, Vol.
FED-258
, pp.
431
437
.
15.
Bardell
,
R.
,
Sharma
,
R.
,
Forster
,
F. K.
,
Afromowitz
,
M. A.
, and
Penney
,
R.
, 1997, “
Designing high-performance micro-pumps based on no-moving-parts valves
,” in
Micro-Electro-Mechanical Systems (MEMS)
, ASME International Mechanical Engineering Congress and Exposition (Dallas),
L.
Lin
,
K. E.
Goodson
et al.
(Eds.), ASME, Vol.
DSC-234∕HTD-354
, pp.
47
53
.
You do not currently have access to this content.