In this paper, flow during the filling and post-filling stages in semiconductor chip encapsulation has been analyzed. A finite-element method based on the Hele-Shaw approximation is used for the flow analysis in the chip cavity. The compressibility of the epoxy-molding compound has been considered to analyze the post-filling stage. The model has been verified by comparing resulting predictions with experimental results. Specifically, pressure has been measured in a rectangular cavity and compared with simulation results. The calculated and experimental results show good agreement. [S1043-7398(00)00101-8]

1.
Manzione, L. T., 1990, Plastic Packaging of Microelectronic Devices, Van Nostrand Reinhold, New York.
2.
Turng
,
L. S.
, and
Wang
,
V. W.
,
1993
, “
On the Simulation of Microelectronic Encapsulation with Epoxy Molding Compound
,”
J. Reinforced Plastics Composites
,
12
, pp.
506
519
.
3.
Han, S., and Wang, K. K., “Flow Analysis in a Chip Cavity During Semiconductor Encapsulation,” ASME J. Electron. Packag., accepted for publication.
4.
Fariss, R. E., and Krueger, S. R., 1987, “Process Control Technology for Plastic Packaging of Microelectronic Devices,” SPE Tech. Pap., pp. 368–371.
5.
Hieber
,
C. A.
, and
Shen
,
S. F.
,
1980
, “
A Finite-Element/Finite-Difference Simulation of the Injection-Molding Filling Process
,”
J. Non-Newtonian Fluid Mech.
,
7
, pp.
1
32
.
6.
Chiang
,
H. H.
,
Hieber
,
C. A.
, and
Wang
,
K. K.
,
1991
, “
A Unified Simulation of the Filling and Postfilling Stages in Injection Molding,” Part I and II
,
Polym. Eng. Sci.
,
31
, pp.
116
139
.
7.
Han
,
S.
,
Wang
,
K. K.
,
Hieber
,
C. A.
, and
Cohen
,
C.
,
1997
, “
Characterization of the Rheological Properties of a Fast-Curing Epoxy Molding Compound
,”
J. Rheol.
,
42
, pp.
177
195
.
8.
Herschel
,
W. H.
, and
Bulkley
,
R.
,
1926
, “
Konsistenzmessungen von Gummi-Benzollosungen
,”
Kolloid-Z.
,
39
, pp.
291
300
.
9.
Williams
,
M. L.
,
Landel
,
R. F.
, and
Ferry
,
J. D.
,
1955
, “
The Temperature Dependence of Relaxation Mechanisms in Amorphous Polymers and Other Glass-Forming Liquids
,”
J. Am. Chem. Soc.
,
77
, pp.
3701
3707
.
10.
Castro
,
J. M.
, and
Macosko
,
C. W.
,
1980
, “
Kinetics and Rheology of Typical Polyurethane Reaction Injection Molding Systems
,”
SPE Tech. Pap.
,
26
, pp.
434
438
.
11.
Kamal, M. R., and Ryan, M. E., 1987, Injection and Compression Molding Fundamentals, chpt. 4, A. I. Isayev, ed., Marcel Dekker, New York.
12.
Lobo
,
H.
, and
Cohen
,
C.
,
1988
, “
Measurement of Thermal Conductivity of Polymer Melts by the Line Source method
,”
SPE Tech. Pap.
,
34
, pp.
609
611
.
13.
Kinlelaar, M., Muzumdar, S., Wang, B., Chiu, Y. Y., and Lee, L. J., 1994, “Dilatometry of Thermoset Resins in Reactive Processing,” SPE Tech. Pap., pp. 951–955.
You do not currently have access to this content.