Magnetically suspended left ventricular assist devices have only one moving part, the impeller. The impeller has absolutely no contact with any of the fixed parts, thus greatly reducing the regions of stagnant or high shear stress that surround a mechanical or fluid bearing. Measurements of the mean flow patterns as well as viscous and turbulent (Reynolds) stresses were made in a shaft-driven prototype of a magnetically suspended centrifugal blood pump at several constant flow rates using particle image velocimetry (PIV). The chosen range of flow rates is representative of the range over which the pump may operate while implanted. Measurements on a three-dimensional measurement grid within several regions of the pump, including the inlet, blade passage, exit volute, and diffuser are reported. The measurements are used to identify regions of potential blood damage due to high shear stress and∕or stagnation of the blood, both of which have been associated with blood damage within artificial heart valves and diaphragm-type pumps. Levels of turbulence intensity and Reynolds stresses that are comparable to those in artificial heart valves are reported. At the design flow rate , the flow is generally well behaved (no recirculation or stagnant flow) and stress levels are below levels that would be expected to contribute to hemolysis or thrombosis. The flow at both high and low flow rates introduces anomalies into the flow, such as recirculation, stagnation, and high stress regions. Levels of viscous and Reynolds shear stresses everywhere within the pump are below reported threshold values for damage to red cells over the entire range of flow rates investigated; however, at both high and low flow rate conditions, the flow field may promote activation of the clotting cascade due to regions of elevated shear stress adjacent to separated or stagnant flow.
Skip Nav Destination
Article navigation
April 2005
Article
PIV Measurements of Flow in a Centrifugal Blood Pump: Steady Flow
James C. McDaniel
James C. McDaniel
The University of Virginia
, Charlottesville, VA 22903
Search for other works by this author on:
Steven W. Day
James C. McDaniel
The University of Virginia
, Charlottesville, VA 22903J Biomech Eng. Apr 2005, 127(2): 244-253 (10 pages)
Published Online: November 18, 2004
Article history
Received:
October 7, 2003
Revised:
September 20, 2004
Accepted:
November 18, 2004
Citation
Day, S. W., and McDaniel, J. C. (November 18, 2004). "PIV Measurements of Flow in a Centrifugal Blood Pump: Steady Flow." ASME. J Biomech Eng. April 2005; 127(2): 244–253. https://doi.org/10.1115/1.1865189
Download citation file:
Get Email Alerts
Related Articles
Decomposition of Deterministic Unsteadiness in a Centrifugal Turbomachine: Nonlinear Interactions Between the Impeller Flow and Volute for a Double Suction Pump
J. Fluids Eng (January,2011)
Hydrodynamic Design of Rotodynamic Pump Impeller for Multiphase Pumping by Combined Approach of Inverse Design and CFD Analysis
J. Fluids Eng (March,2005)
Optimization of an Innovative Rotary Shaft Pump (RSP)
J. Fluids Eng (November,2006)
Steady and Unsteady Radial Forces for a Centrifugal Pump With Impeller to Tongue Gap Variation
J. Fluids Eng (May,2006)
Related Proceedings Papers
Related Chapters
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Introduction
Mixed-flow Pumps: Modeling, Simulation, and Measurements
Introduction
Design and Analysis of Centrifugal Compressors