Magnetic resonance (MR) imaging has been widely used to evaluate the thickness and volume of articular cartilage both in vivo and in vitro. While morphological information on the cartilage can be obtained using MR images, image processing for extracting geometric boundaries of the cartilage may introduce variations in the thickness of the cartilage. To evaluate the variability of using MR images to construct finite element (FE) knee cartilage models, five investigators independently digitized the same set of MR images of a human knee. The topology of cartilage thickness was determined using a minimal distance algorithm. Less than 8 percent variation in cartilage thickness was observed from the digitized data. The effect of changes in cartilage thickness on contact stress analysis was then investigated using five FE models of the knee. One FE model (average FE model) was constructed using the mean values of the digitized contours of the cartilage, and the other four were constructed by varying the thickness of the average FE model by and respectively. The results demonstrated that under axial tibial compressive loading (up to 1400 N), variations of cartilage thickness caused by digitization of MR images may result in a difference of approximately 10 percent in peak contact stresses (surface pressure, von Mises stress, and hydrostatic pressure) in the cartilage. A reduction of cartilage thickness caused increases of contact stresses, while an increase of cartilage thickness reduced contact stresses. Furthermore, the effect of variation of material properties of the cartilage on contact stress analysis was investigated. The peak contact stress increased almost linearly with the Young’s modulus of the cartilage. The peak von Mises stress was dramatically reduced when the Poisson’s ratio was increased from 0.05 to 0.49 under an axial compressive load of 1400 N, while peak hydrostatic pressure was dramatically increased. Peak surface pressure was also increased with the Poisson’s ratio, but with a lower magnitude compared to von Mises stress and hydrostatic pressure. In conclusion, the imaging process may cause 10 percent variations in peak contact stress, and the predicted stress distribution is sensitive to the accuracy of the material properties of the cartilage model, especially to the variation of Poisson’s ratio.
Skip Nav Destination
Article navigation
August 2001
Technical Papers
Variability of a Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee for Joint Contact Stress Analysis
Guoan Li,
Guoan Li
Orthopedic Biomechanics Lab, Harvard Medical School, Massachusetts General Hospital/Beth Israel Deaconess Medical Center, Boston, MA 02215
Search for other works by this author on:
Orlando Lopez,
Orlando Lopez
Orthopedic Biomechanics Lab, Harvard Medical School, Massachusetts General Hospital/Beth Israel Deaconess Medical Center, Boston, MA 02215
Search for other works by this author on:
Harry Rubash
Harry Rubash
Orthopedic Biomechanics Lab, Harvard Medical School, Massachusetts General Hospital/Beth Israel Deaconess Medical Center, Boston, MA 02215
Search for other works by this author on:
Guoan Li
Orthopedic Biomechanics Lab, Harvard Medical School, Massachusetts General Hospital/Beth Israel Deaconess Medical Center, Boston, MA 02215
Orlando Lopez
Orthopedic Biomechanics Lab, Harvard Medical School, Massachusetts General Hospital/Beth Israel Deaconess Medical Center, Boston, MA 02215
Harry Rubash
Orthopedic Biomechanics Lab, Harvard Medical School, Massachusetts General Hospital/Beth Israel Deaconess Medical Center, Boston, MA 02215
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division March 2, 1999; revised manuscript received March 13, 2001. Associate Editor: M. L. Hull.
J Biomech Eng. Aug 2001, 123(4): 341-346 (6 pages)
Published Online: March 13, 2001
Article history
Received:
March 2, 1999
Revised:
March 13, 2001
Citation
Li, G., Lopez , O., and Rubash, H. (March 13, 2001). "Variability of a Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee for Joint Contact Stress Analysis ." ASME. J Biomech Eng. August 2001; 123(4): 341–346. https://doi.org/10.1115/1.1385841
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
Automated Methodology for Determination of Stress Distribution in Human Abdominal Aortic Aneurysm
J Biomech Eng (October,2005)
A New Cemented Hip Prosthesis Concept
J. Med. Devices (June,2011)
Response to Dr. Robert W. Mann
J Biomech Eng (August,2004)
A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
J Biomech Eng (June,2002)
Related Proceedings Papers
Related Chapters
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition
Stress Analysis of Gas Turbine Blade under Different Loads Using Finite Element Modeling
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition