The novel concept of swelling-type intramedullary hip implants that attain self-fixation by an expansion-fit mechanism resulting from controlled swelling of the implant (by absorption of body fluids) was examined in detail using a finite element model of the implant-femur system. Some of the potential advantages of this technique over traditional techniques include enhanced fixation, lower relative micromotions, improved bony ingrowth, and elimination of acrylic cement. The finite element model created in this study incorporated: (i) the major aspects of the three-dimensional geometry of the implant and femur, (ii) the anisotropic elastic properties of bone and implant materials and the changes in orientation of the principal axes of anisotropy along the length of the implant-femur system, (iii) a layer of cancellous bone between the implant and cortical bone in the proximal femoral region, and (iv) frictional sliding between the bone and implant. The model was used to study quantitatively the parametric influence of various material design variables on the micromotions and stress fields in the bone-swelling-type implant system. The results of the finite element analyses were used to establish material behavior goals and provide targets for a material development study.

1.
ABAQUS, 1994, Reference Manuals, Hibbitt, Karlsson, and Sorensen, Inc., Providence, RI.
2.
Bobyn
J. D.
,
Mortimer
E. S.
,
Glassman
A. H.
,
Engh
C. A.
,
Miller
J. E.
, and
Brooks
C. E.
,
1992
, “
Producing and avoiding stress shielding. Laboratory and clinical observations of non-cemented total hip arthoplasty
,”
Clinical Orthopaedics and Related Research
, Vol.
274
, pp.
79
96
.
3.
Brown
T. D.
, and
Ferguson
A. B.
,
1980
, “
Mechanical property distributions in the cancellous bone of the human proximal femur
,”
Acta Orthop. Scand.
, Vol.
51
, pp.
429
437
.
4.
Burke
D. W.
,
Gates
E. I.
, and
Harris
W. H.
,
1984
, “
Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement
,”
J. Bone and Joint Surg.
, Vol.
66-A
:(
8
), pp.
1265
1273
.
5.
Charnley
J.
,
1960
, “
Anchorage of the femoral head prosthesis to the shaft of the femur
,”
J. Bone and Joint Surg.
, Vol.
42-B
, pp.
28
30
.
6.
Cheal
E. J.
,
Spector
M.
, and
Hayes
W. C.
,
1992
, “
Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthoplasty
,”
J. Orthop. Res.
, Vol.
10
, pp.
405
422
.
7.
COSMOS/M, 1994, Reference Manuals, Structural Research and Analysis Corp.
8.
Davies
J. P.
,
Burke
W.
,
O’Connor
D. O.
, and
Harris
W. H.
,
1987
, “
Comparison of the fatigue characteristics of centrifuged and uncentrifuged Simplex-P bone cement
,”
J. Orthopaedic Research
, Vol.
5
, pp.
366
371
.
9.
Davies
J. P.
,
O’Connor
D. O.
,
Burke
W. B.
,
Jasty
M. J.
, and
Harris
W. H.
,
1988
, “
The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities
,”
Clin. Orthop.
, Vol.
229
, pp.
156
161
.
10.
Davies
J. P.
,
Jasty
M.
,
O’Connor
D. O.
,
Burke
D. W.
,
Harrigan
T. P.
, and
Harris
W. H.
,
1989
, “
The effect of centrifuging bone cement
,”
J. Bone Joint Surg.
, Vol.
71-B
, pp.
39
42
.
11.
Engh
C. A.
,
O’Connor
D.
,
Jasty
M.
,
McGovern
T. F.
,
Bobyn
J. D.
, and
Harris
W. H.
,
1992
, “
Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prosthesis
,”
Clinical Orthopaedics and Related Research
, Vol.
285
, pp.
13
30
.
12.
Greenberg, A. R., 1978, “Development of a polymer-ceramic composite material for endosseous implant applications,” Ph.D. Dissertation, Drexel University, Philadelphia, PA.
13.
Greenberg
A. R.
,
Kamel
I. L.
,
Dubin
S.
, and
Miller
A.
,
1978
, “
Stimulation of Bone Formation by a Swelling Endosseous Implant
,”
J. Biomed. Mat. Res.
, Vol.
12
, pp.
929
933
.
14.
Harrigan
T. P.
, and
Harris
W. H.
,
1991
, “
A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components
,”
J. Biomechanics
, Vol.
24
, pp.
1047
1058
.
15.
Huiskes, R., Janssen, J. D., and Slooff, T. J., 1981, “A Detailed Comparison of Experimental and Theoretical Stress-Analyses of a Human Femur,” Mechanical Properties of Bone, ASME, New York, p. 211.
16.
Huiskes
R.
,
Weinans
H.
, and
Van Rietbergen
B.
,
1992
, “
The relationship between stress shielding and bone resorption around total hip stems and effects of flexible materials
,”
Clinical Orthopaedics and Related Research
, Vol.
274
, pp.
124
134
.
17.
Jasty
M.
,
Maloney
W. J.
,
Bragdon
C. R.
,
Haire
T.
, and
Harris
W. H.
,
1990
, “
Histomorphological studies of the long-term skeletal responses to well fixed cemented femoral components
,”
J. Bone Joint Surg.
, Vol.
72A
, pp.
1220
1229
.
18.
Kalidindi, S. R., and Abusafieh, A., 1996, “Longitudinal and Transverse Moduli and Strengths of 3-D Braided Textile Composites With Low Braid Angles,” Journal of Composite Materials, in press.
19.
Katz
R. L.
,
Bourne
R. B.
,
Rorabeck
C. H.
, and
McGee
H.
,
1992
, “
Total hip arthoplasty in patients with avascular necrosis of the hip. Follow-up observations on cementless and cemented hip prosthesis
,”
Clin. Orthop.
, Vol.
281
, pp.
145
51
.
20.
Kim
Y. H.
, and
Kim
V. E.
,
1993
, “
Early migration of uncemented porous coated anatomic femoral component related to aseptic loosening
,”
Clin. Orthop.
, Vol.
295
, pp.
146
55
.
21.
Ko, F. K., 1989, “Three dimensional Fabrics for Composites,” Textile Structural Composites, Chou, T. W., and Ko, F. K., eds., Elsevier Science Publishers, Amsterdam, pp. 129–171.
22.
Lins
R. E.
,
Barnes
B. C.
,
Callaghan
J. J.
,
Mair
S. D.
, and
McCollum
D. E.
,
1993
, “
Evaluation of uncemented total hip arthroplasty in patients with avascular necrosis of the femoral head
,”
Clin. Orthop.
, Vol.
297
, pp.
168
73
.
23.
Marie
Z.
, and
Karpman
R. R.
,
1992
, “
Early failure of noncemented porous coated anatomic total hip arthroplasty
,”
Clin. Orthop.
, Vol.
278
, pp.
116
20
.
24.
McCoy
T. H.
,
Salvati
E. A.
,
Ranawat
C. S.
, and
Wilson
P. D.
,
1988
, “
A fifteen-year follow up study of one hundred Charnley low-friction arthroplasties
,”
Orthop. Clin. No. Amer.
, Vol.
19
, pp.
467
476
.
25.
Pilliar
R. M.
, and
Blackwell
R.
,
1976
, “
Carbon fiber-reinforced bone cement in orthopedic surgery
,”
J. Biomed. Mater. Res.
, Vol.
10
, pp.
893
906
.
26.
Rimnac
C. M.
,
Wright
T. M.
, and
McGill
D. L.
,
1986
, “
The effect of centrifugation on the fracture properties of acrylic bone cements
,”
J. Bone Joint Surg.
, Vol.
68-A
:(
2
), pp.
281
287
.
27.
Sarmiento
A.
,
Natarajan
V.
,
Gruen
T. A.
, and
McMahon
M.
,
1988
, “
Radiographic performance of two different total hip cemented arthroplasties
,”
Orthop. Clin. No. Amer.
, Vol.
19
, pp.
505
515
.
28.
Sharda
A. N.
, and
Kamel
I. L.
,
1990
, “
A Dynamic Implant for the Development of a Hip Stem Prosthesis
,”
Annual International Conference of the IEEE Engineering in Medicine and Biology Society
, Vol.
12
, p.
2182
2182
.
29.
Sharda, A. N., 1993, Ph.D. Thesis, Biomedical Engineering and Science Institute.
30.
Stauffer
R. N.
,
1982
, “
Ten-year follow-up study of total hip replacement
,”
J. Bone and Joint Surg.
, Vol.
64-A
, pp.
983
990
.
31.
Sutherland
C. J.
,
Wilde
A. H.
,
Borden
L. S.
, and
Marks
K. E.
,
1982
, “
A ten-year follow up of one hundred consecutive Muller curved-stem total hip replacement arthroplasties
,”
J. Bone and Joint Surg.
, Vol.
64-A
, pp.
970
982
.
32.
Tanzer
M.
,
Maloney
W. J.
,
Jasty
M.
, and
Harris
W. H.
,
1992
, “
The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement
,”
J. Bone Joint Surg.
, Vol.
74
(
3
), pp.
404
410
.
33.
Tensi
H. M.
,
Gese
H.
, and
Ascherl
R.
,
1989
, “
Non-linear Three-Dimensional Finite Element Analysis of a Cementless Hip Endoprosthesis
,”
J. Engineering in Medicine
, Vol.
203
, pp.
215
222
.
34.
Van Buskirk
W. C.
,
Cowin
S. C.
, and
Ward
R. N.
,
1981
, “
Ultrasonic measurement of orthotropic elastic constants of bovine femoral bone
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
103
, pp.
67
72
.
35.
Van Rietbergen
B.
,
Huiskes
R.
,
Weinans
H.
,
Sumner
D. R.
,
Turner
T. M.
, and
Galante
J. O.
,
1993
, “
The mechanism of bone remodeling and resorption around press-fitted THA stems
,”
J. Biomech.
, Vol.
26
, pp.
369
382
.
This content is only available via PDF.
You do not currently have access to this content.