The finite element method has been used to analyze hip prostheses for the past 25+ years and has proven to be quite effective. The use of finite element analysis, initially, was restricted to duplicating experimental results but has progressed over the decades in step with the computational capabilities as well as the increased understanding of hip replacement procedures. The mechanics of the bone-prosthesis system is quite complicated in the context of the geometry, material properties, loading and the interaction between the femur and the hip stem. The following article is a survey of the finite element technique as applied by researchers over the past three decades, within given limitations, to solve this complex problem. The discussion is limited to the analysis of the femoral component and consists of the approximations, methodologies and conclusions as reported. Relevant experimental results have also been reviewed. There are 136 references cited.
Skip Nav Destination
e-mail: santare@me.udel.edu
Article navigation
January 2000
Review Articles
Survey of Stress Analyses of the Femoral Hip Prosthesis
Makarand G. Joshi,
Makarand G. Joshi
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
Search for other works by this author on:
Michael H. Santare,
Michael H. Santare
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
e-mail: santare@me.udel.edu
Search for other works by this author on:
Suresh G. Advani
Suresh G. Advani
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
Search for other works by this author on:
Makarand G. Joshi
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
Michael H. Santare
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
e-mail: santare@me.udel.edu
Suresh G. Advani
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
Appl. Mech. Rev. Jan 2000, 53(1): 1-18 (18 pages)
Published Online: January 1, 2000
Article history
Online:
April 9, 2009
Citation
Joshi, M. G., Santare, M. H., and Advani, S. G. (January 1, 2000). "Survey of Stress Analyses of the Femoral Hip Prosthesis." ASME. Appl. Mech. Rev. January 2000; 53(1): 1–18. https://doi.org/10.1115/1.3097335
Download citation file:
Get Email Alerts
Cited By
Mechanical Properties Inside Origami-Inspired Structures: An Overview
Appl. Mech. Rev (January 2025)
Statistical Scaling in Localization-Induced Failures
Appl. Mech. Rev (November 2024)
Related Articles
Stress Analysis and Failure Prediction in the Proximal Femur Before and After Total Hip Replacement
J Biomech Eng (February,1986)
Simulation of Physiological Loading in Total Hip Replacements
J Biomech Eng (August,2006)
Effect of Geometrical Uncertainty on Cemented Hip Implant Structural Integrity
J Biomech Eng (May,2009)
A New Cemented Hip Prosthesis Concept
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Conclusion
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Approximate Analysis of Plates
Design of Plate and Shell Structures